Manual
Configuration of the camera
MARLIN Technical Manual V2.4.0
227
Note
L
SIS outside the visible image area:
For certain Format_7 modes the image frame transported may
contain padding (filling) data at the end of the transported
frame. Setting LinePos=HeightOfImage places the stamp in
this padding data area, outside the visible area (invisible
SIS).
If the transported image frame does not contain any padding
data the camera will not relocate the SIS to the visible area
automatically (no SIS).
Take in mind that the accuracy of the time stamp might be
affected by asynchronous traffic – mainly if image settings
are changed.
Note
L
The IEEE 1394 cycle counter will be inserted into the very
first 4 bytes/pixels of a line.
Cycle offset Cycles Seconds
Cycle offset 12 bit Cycle count 13 bit Second count 7 bit
0 .. 3071 cycle offsets (40.69 ns) 0 .. 7999 cycles 0 .. 127 seconds
24.576 MHz cycle timer counter 8000 Hz cycle timer counter 1 Hz cycle timer counter
Table 124: 32-bit cycle timer layout
Bit0123456789101112131415
Cycle offset 12 bit Cycle count ...
Bit16171819202122232425262728293031
... Cycle count 13 bit Second count 7 bit