Instruction manual

Configuration of the camera
Guppy PRO Technical Manual V2.0.3
217
Extended version information register
The presence of each of the following features can be queried by the 0 bit of
the corresponding register.
0xF1000800
0xF1000804
IO_OUTP_PWM1 Guppy PRO housing
See Table 28: PWM configuration registers on page
73
0xF1000808
0xF100080C
IO_OUTP_PWM2
0xF1000810
0xF1000814
IO_OUTP_PWM3
0xF1000840 IO_INP_DEBOUNCE_1 See Table 57: Advanced register: Debounce time
for input ports on page 140
0xF1000850 IO_INP_DEBOUNCE_2
0xF1000860 IO_INP_DEBOUNCE_3
0xF1000870 IO_INP_DEBOUNCE_4
0xF1000FFC GPDATA_INFO See Table 138: Advanced register: GPData buffer
on page 248
0xF1001000
...
0xF100nnnn
GPDATA_BUFFER
Note
Advanced features should always be activated before access-
ing them.
Note
Currently all registers can be written without being
activated. This makes it easier to operate the camera
using Directcontrol.
AVT reserves the right to require activation in future
versions of the software.
Register Name Field Bit Description
0xF1000010 VERSION_INFO1 µC type ID [0..15] Always 0
µC version [16..31] Bcd-coded version number
0xF1000014 VERSION_INFO1_EX µC version [0..31] Bcd-coded version number
Table 110: Advanced register: Extended version information
Register Register name Description
Table 109: Advanced registers summary