Instruction manual
Configuration of the camera
Guppy PRO Technical Manual V2.0.3
217
Extended version information register
The presence of each of the following features can be queried by the 0 bit of
the corresponding register.
0xF1000800
0xF1000804
IO_OUTP_PWM1 Guppy PRO housing
See Table 28: PWM configuration registers on page
73
0xF1000808
0xF100080C
IO_OUTP_PWM2
0xF1000810
0xF1000814
IO_OUTP_PWM3
0xF1000840 IO_INP_DEBOUNCE_1 See Table 57: Advanced register: Debounce time
for input ports on page 140
0xF1000850 IO_INP_DEBOUNCE_2
0xF1000860 IO_INP_DEBOUNCE_3
0xF1000870 IO_INP_DEBOUNCE_4
0xF1000FFC GPDATA_INFO See Table 138: Advanced register: GPData buffer
on page 248
0xF1001000
...
0xF100nnnn
GPDATA_BUFFER
Note
Advanced features should always be activated before access-
ing them.
Note
• Currently all registers can be written without being
activated. This makes it easier to operate the camera
using Directcontrol.
• AVT reserves the right to require activation in future
versions of the software.
Register Name Field Bit Description
0xF1000010 VERSION_INFO1 µC type ID [0..15] Always 0
µC version [16..31] Bcd-coded version number
0xF1000014 VERSION_INFO1_EX µC version [0..31] Bcd-coded version number
Table 110: Advanced register: Extended version information
Register Register name Description
Table 109: Advanced registers summary