Instruction manual

Marlin Technical ManualV.2.7.0
205
Configuration of the camera
Look-up tables (LUT)
Load the look-up tables to be used into the camera and choose the look-up table
number via the LutNo field. Now you can activate the chosen LUT via the LUT_C-
TRL register.
The LUT_INFO register indicates how many LUTs the camera can store and shows
the maximum size of the individual LUTs.
The possible values for LutNo are 0..n-1, whereas n can be determined by read-
ing the field NumOfLuts of the LUT_INFO register.
Register Name Field Bit Description
0xF1000220 SEQUENCE_CTRL Presence_Inq [0] Indicates presence of this fea-
ture (read only)
--- [1..4] Reserved
AutoRewind [5]
ON_OFF [6] Enable/Disable this feature
--- [7..15] Reserved
MaxLength [16..23] Maximum possible length of a
sequence (read only)
SeqLength [24..31] Length of the sequence
0xF1000224 SEQUENCE_PARAM --- [0..4] Reserved
ApplyParameters [5] Apply settings to selected
image of sequence; auto-reset
IncImageNo [6] Increment ImageNo after
ApplyParameters has finished
--- [7..23] Reserved
ImageNo [24..31] Number of image within a
sequence
Table 105: Sequence control register
Register Name Field Bit Description
0xF1000240 LUT_CTRL Presence_Inq [0] Indicates presence of this fea-
ture (read only)
--- [1..5] Reserved
ON_OFF [6] Enable/Disable this feature
--- [7..25] Reserved
LutNo [26..31] Use look-up table with LutNo
number
Table 106: Advanced register: LUT