Instruction manual
Marlin Technical ManualV.2.7.0
215
Configuration of the camera
E.g. if the active image size is 640 x 480 pixel the camera accepts a maximum of
640 x 512 pixel as the auto function AOI work area (if the control area position
is 0:0).
Another case is for outdoor applications: the sky will be excluded from the gen-
eration of the reference levels.
Color correction
For an explanation of the color correction matrix and for further information
read Chapter Color interpolation and correction on page 99.
Trigger delay
The advanced register allows start of the integration to be delayed via
DelayTime by max. 2
21
μs, which is max. 2.1 s after a trigger edge was detected.
Register Name Field Bit Description
0xF10003A0 COLOR_CORR Presence_Inq [0] Indicates presence of this
feature (read only)
--- [1..5] Reserved
ON_OFF [6] Color correction on/off
default: on
Write: 02000000h to switch
color correction OFF
Write: 00000000h to switch
color correction ON
--- [7..31] Reserved
Table 118: Advanced register: Color correction
Register Name Field Bit Description
0xF1000400 TRIGGER_DELAY Presence_Inq [0] Indicates presence of this
feature (read only)
--- [1..5] Reserved
ON_OFF [6] Trigger delay on/off
--- [7..10] Reserved
DelayTime [11..31] Delay time in μs
Table 119: Advanced register: Trigger Delay