Instruction manual
Marlin Technical ManualV.2.7.0
217
Configuration of the camera
Secure image signature (SIS)
Definition Secure image signature (SIS) is the synonym for data, which is inserted into an
image to improve or check image integrity.
With the new firmware V3.03, all CCD Marlin models can insert
• Time stamp (1394 bus cycle time at the beginning of integration)
• Frame counter (frames read out of the sensor)
• Trigger counter (external trigger seen only)
into a selectable line position within the image. Time stamp, frame counter and
trigger counter are available as advanced registers to be read out directly.
Advanced register: time stamp
The time stamp feature is controlled by the following advanced feature register:
Note
When SOFT_RESET has been defined, the camera will respond
to further read or write requests but will not process them.
Register Name Field Bit Description
0xF1000600 TIMESTAMP Presence_Inq [0] Indicates presence of this
feature (read only)
--- [1..5] Reserved
ON_OFF [6] SIS (time stamp) on/off
--- [7] Reserved
Format_0_Inq [8] Presence of Format_0
0: n/a
1: available
--- [9] Reserved
--- [10] Reserved
--- [11] Reserved
--- [12] Reserved
--- [13..15] Write as 0.
Reserved
LinePos [16..31] Line position of SIS
(time stamp)
Table 122: Advanced register: Time stamp