Configuration of the camera
Advanced register: trigger counter
The trigger counter feature is controlled by the following advanced feature reg-
ister:
Having this feature enabled, the current trigger counter value (external trigger
seen by hardware) will be inserted as a 32-bit integer value into any captured
image.
Setting the Reset flag to 1 resets the trigger counter to 0 – the Reset flag is self-
cleared.
The ON_OFF and LinePos fields are simply mirrors of the time stamp feature. Set-
tings of these fields are applied to all image stamp features.
Additionally there is a register for direct read out of the trigger counter value.
Register Name Field Bit Description
0xF1000620 TRGCNT_STAMP Presence_Inq [0] Indicates presence of this
feature (read only)
Reset [1] Reset trigger counter
--- [2..5] Reserved
ON_OFF [6] SIS (time stamp) on/off
--- [7] Reserved
--- [8..15] Reserved
LinePos [16..31] Line position of SIS
(time stamp)
0xF1000624 TRGCNT [0..31] Trigger counter
Table 126: Advanced register: Trigger counter
Note
The 4 bytes of the trigger counter value will be inserted as the
9th to 12th byte of a line.