Instruction manual

Configuration of the camera
MARLIN Technical Manual
Page 98
11.3.10 Feature control error status register
Offset Name Notes
640h Feature_Control_Error_Status_HI always 0
644h Feature_Control_Error_Status_LO always 0
Table 58: Feature control error register
11.3.11 Video mode control and status registers for Format_7
The offset to the base address is in V_CSR_INQ_7_x. The offset 100h must be added for Mode 1,
200h for Mode 2 200h and 300h for Mode 3.
Offset Name Notes
000h MAX_IMAGE_SIZE_INQ
004h UNIT_SIZE_INQ
008h IMAGE_POSITION
00Ch IMAGE_SIZE See above
010h COLOR_CODING_ID See above
014h COLOR_CODING_INQ See above
034h PIXEL_NUMER_INQ
038h TOTAL_BYTES_HI_INQ
03Ch TOTAL_BYTES_LO_INQ
040h PACKET_PARA_INQ See above
044h BYTE_PER_PACKET See above
Table 59: Format_7 control and status register
For all modes in Format_7, ErrorFlag_1 and ErrorFlag_2 are refreshed on each access to the
Format_7 Register.
Contrary to IIDC DCAM v. 1.3, registers relevant to Format_7 are refreshed on each access.
The “Setting_1” bit is automatically cleared after each access.
When ErrorFlag_1 or ErrorFlag_2 is set and Format_7 is configured, no image capture is
started.
Contrary to IIDC v.1.3, COLOR_CODING_ID is set to a default value after an INITIALIZE or
“reset”.
Contrary to IIDC DCAM v.1.3, the UnitBytePerPacket field is already filled in with a fixed
value in the PACKET_PARA_INQ register.