Which new sequence mode features are
available?
New features:
Repeat one step of a sequence n times where n can be set by the variable
ImageRepeat in SEQUENCE_PARAM.
Define one or two hardware inputs in Input mode field of IO_INP_CTRL as:
Sequence step input (if two are set as input, they are AND gated) or
Sequence reset input
Setup mode
The SetupMode flag allows you to set up a sequence while capturing images.
Using this flag you get a visual feedback of the settings. Set this flag when set-
ting up the sequence and reset the flag before using the sequence.
I/O controlled sequence stepping mode
The I/O controlled sequence stepping mode can be done level controlled or
edge controlled:
The I/O controlled sequence stepping mode can be set for every single sequence
entry. Thus a sequence can be controlled in a very flexible manner.
Note
From now on:
sequence step is I/O controlled sequence stepping mode
sequence reset is I/O controlled sequence pointer reset
Level controlled Edge controlled
As long as the input is in high
state the sequence pointer will be
incremented from image to
image.
Can be combined with Quick For-
mat Change Modes. See Chapter
Standard Parameter Update Tim-
ing on page 185 and Chapter
New: Quick Format Change Mode
(QFCM) on page 185.
Level change is asynchronous to
image change.
A rising edge on the input will
cause one pointer increment
immediately.
Can be combined with Quick For-
mat Change Modes. See Chapter
Standard Parameter Update Tim-
ing on page 185 and Chapter
New: Quick Format Change Mode
(QFCM) on page 185.
Table 82: Description of sequence stepping control