User Manual
Introduction
PIKE Technical Manual V5.1.2
24
continued from last page
V5.0.1
[continued]
08.06.10
[continued]
Changed and new CAD drawings for Pike F-1100/1600:
• Changed CAD drawings with corrected mount dimensions:
see Figure 27: Pike F-Mount dimensions (standard for Pike
F-1100 and Pike F-1600) on page 72, Figure 34: Pike M42-
Mount dimensions (optional for Pike F-1100 and Pike F-
1600) on page 79 and Figure 40: Pike M58-Mount dimen-
sions (optional for Pike F-1100 and Pike F-1600) on page
85.
• Added CAD drawings for Pike F-1100/1600 GOF versions
incl. W270 models: Chapter Camera dimensions on page
50ff.
V5.0.2 09.08.10 Changed sensitivity curve:
• For Pike F-032B: due to new KODAK sensor data sheet for
KAI-0340, the new sensitivity curve was added, see Figure
41: Spectral sensitivity of Pike F-032B on page 103.
Changed trigger diagram:
• Added trigger delay and connection between trigger delay
and Busy signal, see Figure 63: Output impulse diagram on
page 124
New file format:
• Converted FrameMaker files from FM7 to FM9
Improved description of HSNR mode:
• Added info that for 8-bit video modes, the internal HSNR
calculations are done with 14 bit: Chapter High SNR mode
(High Signal Noise Ratio) on page 168
to be continued on next page
Version Date Remarks
Table 1: Document history