User Manual
Configuration of the camera
PIKE Technical Manual V5.1.2
366
Advanced register: frame counter
The frame counter feature is controlled by the following advanced feature reg-
ister:
Having this feature enabled, the current frame counter value (images read out
of the sensor, equivalent to # FrameValid) will be inserted as a 32-bit integer
value into any captured image.
Setting the Reset flag to 1 resets the frame counter to 0: the Reset flag is self-
cleared.
Additionally there is a register for direct read out of the frame counter value.
Note
Different to Marlin SIS:
Register 610 is only to be used to reset the frame counter.
Register Name Field Bit Description
0xF1000610 FRMCNT_STAMP Presence_Inq [0] Indicates presence of this feature
(read only)
Reset [1] Reset frame counter
--- [2..31] Reserved
0xF1000614 FRMCNT [0..31] Frame counter
Table 187: Advanced register: Frame counter
Note
The 4 bytes of the frame counter value will be inserted as the
5th to 8th byte of a line.