Instruction manual

Table Of Contents
Controlling image capture
PIKE Technical Manual V4.0.0
185
Figure 96: Data flow and timing after end of exposure
OneShot Command
Decode command
Exposure
Integration-Start
Timebase Reg.
X
Shutter-Reg.
Offset
Processing Delay
< 150 μs
Pike F-032: 17 µs
Pike F-100: 42 µs
Pike F-145: 38 µs
Pike F-145-15fps: 70 µs
Pike F-210: 42 µs
Pike F-421: 69 µs
Pike F-505: 26 µs
Timebase x Shutter + Offset = Exposure Time
First Packet on Bus
< 710 μs
+/-62.5 μs