Instruction manual

Table Of Contents
Configuration of the camera
PIKE Technical Manual V4.0.0
280
0XF1000440 LOW_SMEAR see Chapter Smear reduction on page 317
0XF1000510 SOFT_RESET see Table 156: Soft reset register on page 305
0XF1000520 HIGH_SNR see Table 157: High Signal Noise Ratio (HSNR) on
page 306
0X1000550 USER PROFILES see Table 169: User profiles on page 317
0X1000620 TRIGGER_COUNTER see Table 166: Advanced register: trigger counter
on page 315
0X1000630 SIS
0X1000560 F7MODE_MAPPING see Format_7 mode mapping on page 310
0X1000570 PARAMUPD_TIMING see Chapter Quick parameter change timing modes
on page 307
0XF1000FFC GPDATA_INFO see Table 172: GPData buffer register on page 320
0XF1001000
...
0XF100nnnn
GPDATA_BUFFER
0x1100000 PARRAMLIST_INFO see Chapter Parameter-List Update on page 309
0x1101000 PARAMLIST_BUFFER
Note
L
Advanced features should always be activated before access-
ing them.
Note
L
Currently all registers can be written without being
activated. This makes it easier to operate the camera
using Directcontrol.
AVT reserves the right to require activation in future
versions of the software.
Register Register name Remarks
Table 133: Advanced registers summary