Instruction manual

Table Of Contents
Configuration of the camera
PIKE Technical Manual V4.0.0
302
The possible increment of the work area position and size is defined by the
YUNITS and XUNITS fields. The camera automatically adjusts your settings to
permitted values.
0xF1000398 AF_AREA_SIZE Width [0..15] Width of work area size
Height [16..31] Height of work area size
Note
L
If the adjustment fails and the work area size and/or work
area position becomes invalid, then this feature is automat-
ically switched off.
Read back the ON_OFF flag, if this feature does not work as
expected.
Register Name Field Bit Description
Table 151: Advanced register for autofunction AOI