Instruction manual

Table Of Contents
Controlling image capture
PIKE Technical Manual V3.1.0
150
Trigger delay
As already mentioned earlier the cameras feature various ways to delay image
capture based on external trigger.
With IIDC V1.31 there is a standard CSR at Register F0F00534/834h to control
a delay up to FFFh x time base value. The following table explains the Inquiry
register and the meaning of the various bits.
Register Name Field Bit Description
0xF0F00534 TRIGGER_DLY_INQUIRY Presence_Inq [0] Indicates presence of this fea-
ture (read only)
Abs_Control_Inq [1] Capability of control with abso-
lute value
-[2]Reserved
One_Push_Inq [3] One Push auto mode (controlled
automatically by the camera
once)
ReadOut_Inq [4] Capability of reading out the
value of this feature
On_Off_Inq [5] Capability of switching this fea-
ture ON and OFF
Auto_Inq [6] Auto Mode (controlled automat-
ically by the camera)
Manual_Inq [7] Manual Mode (controlled by
user)
Min_Value [8..19] Minimum value for this feature
Max_Value [20..31] Maximum value for this feature
Table 58: Trigger Delay Inquiry register