One-Shot command on the bus to start of
exposure
The following sections describe the time response of the camera using a sin-
gle frame (OneShot) command. As set out in the IIDC specification, this is a
software command that causes the camera to record and transmit a single
frame.
The following values apply only when the camera is idle and ready for use.
Full resolution must also be set.
Microcontroller-Sync is an internal signal. It is generated by the microcon-
troller to initiate a trigger. This can either be a direct trigger or a release for
ExSync if the camera is externally triggered.
End of exposure to first packet on the bus
After the exposure, the CCD sensor is read out; some data is written into the
FRAME_BUFFER before being transmitted to the bus.
The time from the end of exposure to the start of transport on the bus is:
710 µs ± 62.5 µs
This time 'jitters' with the cycle time of the bus (125 µs).
# Read/
Write
Address Value Description
7 wr F0F0061C 80000000 Do one-shot.
6 rd F0F0061C 00000000 Read out one-shot register.
5 wr F0F00830 82000000 Switch on external trigger mode 0.
4 rd F0F00830 80000000 Check trigger status.
3 wr F0F00614 00000000 Stop Free-run.
2 rd F0F00614 80000000 Check Iso_Enable mode (ÆFree-run).
1 rd F0F00614 00000000 This line is produced by SmartView.
Table 65: One-shot control: descriptions
Feature Value
OneShot Æ Microcontroller-Sync 150 µs (processing time in the
microcontroller)
µC-Sync/ExSync Æ Integration-Start 8 µs
Table 66: Values for one-shot