Output features are configured by software. Any signal can be placed on any
output.
The main features of output signals are described below:
Figure 46: Output schematics: switching times
Parameter Symbol Value Condition
Delay time t
d
1.00 µs
OutVCC = 5 V
Resistor value = 1 kΩ
Rise time t
r
2.60 µs
Storage time t
s
48.00 µs
Fall time t
f
400.00 µs
Signal Description
IntEna (Integration Enable) signal This signal displays the time in which exposure
was made. By using a register this output can be
delayed by up to 1.05 seconds.
Fval (Frame valid) signal This feature signals readout from the sensor. This
signal Fval follows IntEna.
Busy signal This indicator appears when the exposure is being
made; the sensor is being read from or data trans-
mission is active. The camera is busy.
Table 37: Output signals