User manual

APS User Manual
329
1.4.5-3 VeriPHY
This section is used for running the VeriPHY Cable Diagnostics. Press to run the diagnostics. This will
take approximately 5 seconds. If all ports are selected, this can take approximately 15 seconds.
When completed, the page refreshes automatically, and you can view the cable diagnostics results in
the cable status table. Note that VeriPHY is only accurate for cables of length 7 -140 meters.10 and
100 Mbps ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or
100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.
Web Interface
To perform a VeriPHY Cable Diagnostic test via the Web Interface:
1. Specify the port in which you wish to perform a test.
2. Click Start to perform the test.
Parameter Description
Port: The physical port of the switch.
Cable Status: Port: Port number.
Pair: The status of the cable pair.
Length: The length (in meters) of the cable pair.
Fig. 159 VeriPHY Cable Diagnostic Test