User's Manual

50
INPUT / OUTPUT
1) One RS-232 port for configuration
2) One RS-232 port for communication
3) One isolated control output N.C. relay for alarm indication
(default) or other control usages
4) One isolated status input channel with 5 mA constant current
sink for external device status input (e.g. read light fault, light
on/off, etc.)
5) Four ADC channels for external sensors
6) VHF connector (M Type)
7) VHF connector (TNC Type)
8) More extra I/O interfaces can be supplied via optional
extension I/O board
CONNECTOR
1) VHF connector (M type)
2) GPS connector (TNC type)
PHYSICAL
Size in mm (w)
140 mm
Size in mm (h)
155 mm
Size in mm (d)
60 mm
Weight
1.5 kg
Case Material
Aluminum Alloy