Installation Instructions

Thickness
(inch)
Fastener
Spacing
Stud
Spacing
(inches)
Height of
Building
(feet)
Maximum basic wind speed
(mph) for exposure category
1
B
C
1/4”
4d box 1½
inch long
nails
4
6 inches on
center
2 by 4
wood
5
15
20
40
60
Fastener
Type
D
IBC, IRC
2
UBC
3
125
120
110
105
100
100
85
85
85
85
--
--
105
100
90
85
80
80
70
70
70
70
--
--
16”
MAXIMUM WIND LOADS FOR MaxiSOFFIT
TM
1 N/A – not applicable
2 Basic wind speed is the 3-second gust, miles per hour (km/hr), in accordance with IBC Section 1609.3 and IRC Section R301.2.
3 Basic wind speed is the fastest mile speed in accordance with UBC Section 1616.
4 Nail has 0.09-inch -diameter shank and 0.218-inch-diameter head.
Frame
Type
APPROVALS: In accordance with ICC-ES Legacy Report ESR-1381, MaxiSOFFIT
TM
is compliant with the following
codes: 2006 International Building Code (IBC) and 2006 International Residential Code (IRC) . MaxiSOFFIT
TM
is also
recognized for application in the following: City of Los Angeles Research Report No. 25252, State of Florida listing
FL # 11009, U.S. Dept. of HUD Materials Release 1338, Texas Department of Insurance Product Evaluation EC-56,
and listing in Wildland Urban Interface Handbook (WUI). These documents should also be consulted for additional
Additional Installation Information, Warranties, and Warnings are available at www.maxitile.com.
MAXITILE, INC. 12950 Country Parkway, Suite 180. San Antonio, TX 78216. Ph: (800) 451-2003. Fax: (210) 545-7315
e-mail: customer.service@maxitile.com
www.maxitile.com
Version: S-MSF-E1-071910
6
MaxiSOFFIT
TM
| www.maxitile.com
B
C
D
5 Wood specic gravity is 0.42 or higher.