Technical Specifications

ICC-ES Evaluation Report ESR-1668
Reissued October 2016
This report is subject to renewal October 2017.
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council
®
DIVISION: 07 00 00THERMAL AND MOISTURE
PROTECTION
Section: 07 46 46Fiber-Cement Siding
REPORT HOLDER:
PLYCEM USA, INC.
FIBER CEMENT PRODUCTS
15055 WOODHAM DRIVE
HOUSTON, TEXAS 77073
(281) 742-7074
www.allurausa.com
EVALUATION SUBJECT:
ALLURA™ FIBER CEMENT LAP SIDING, VERTICAL
PANEL SIDING, SOFFIT PANELS AND SHAPES SIDING
1.0 EVALUATION SCOPE
1.1 Compliance with the following codes:
2012, 2009 and 2006 International Building Code
®
(IBC)
2012, 2009 and 2006 International Residential Code
®
(IRC)
2013 Abu Dhabi International Building Code (ADIBC)
The ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced
in this report are the same sections in the ADIBC.
Properties evaluated:
Weather resistance
Transverse loading
Surface burning characteristics
Non-combustibility
Fire-resistive-rated construction
1.2 Evaluation to the following green code(s)
and/or standards:
2016 California Green Building Standards Code
(CALGreen), Title 24, Part 11
2015, 2012 and 2008 ICC 700 National Green Building
Standard™ (ICC 700-2015, ICC 700-2012 and
ICC 700-2008)
Attributes verified:
See Section 3.0
2.0 USES
Plycem USA’s Allura™ fiber cement lap and panel
products are intended for use as exterior wall coverings
and soffits.
3.0 DESCRIPTION
Allura™ products are autoclaved, single-faced wall
coverings manufactured from a proprietary mixture
of cellulose fiber, portland cement, silica, clay or fly ash
and limestone. See Table 1 for dimensions and surface
texture. Design wind pressures must be determined in
accordance with the applicable code. See Table 2 for
allowable wind pressures, fastener schedules, and
installation requirements. Wind pressures noted in Table 2
are allowable values for positive and negative directions.
Allura™ fiber cement sidings exhibit a flame-spread
index of 25 or less and smoke-developed index of 450 or
less when tested in accordance with ASTM E84.
Allura™ fiber cement is classified as non-combustible
when tested in accordance with ASTM E136.
Allura™ lap and vertical panel siding products are
recognized in this report as components of a one-hour,
fire-resistance-rated, limited-load-bearing, wood-stud wall
assembly, when installed in accordance with Section 4.7 of
this report.
Lap siding, vertical panel siding, soffit panels and
shapes siding come in lengths and widths as noted in
Table 1. All edges are square. Shapes siding is a panel-
type product available with various designs.
The attributes of the stone veneer have been verified
as conforming to the requirements of (i) 2013 CALGreen
Section A4.405.1.3 for prefinished building materials
and Section A5.406.1.2 for reduced maintenance; (ii)
ICC 700-2015 and ICC 700-2012 Sections 601.7,
11.601.7, and 12.1(A).601.7 for site-applied finishing
materials; and (iii) ICC 700-2008 Section 601.7 for
site-applied finishing materials. Note that decisions on
compliance for those areas rest with the user of this report.
The user is advised of the project-specific provisions that
may be contingent upon meeting specific conditions, and
the verification of those conditions is outside the scope of
this report. These codes or standards often provide
supplemental information as guidance.
4.0 INSTALLATION
4.1 General:
The lap, vertical panel and shapes sidings must be
installed over nominally 2-inch-thick wood framing
members; minimum No. 20 gage [0.036 inch (0.91 mm)],
3.625-inch-by-1.375-inch (92 by 34.9 mm), 33 ksi steel,
C-stud framing members; or minimum
7
/
16
-inch structural
wood sheathing as specified in Table 2. A water-resistive
barrier and sheathing must be installed behind the siding in
accordance with the applicable code. Fasteners must be
spaced no closer than
3
/
4
inch (19.1 mm) from the panel
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 9