Installation Instructions

Cut ends must be re-sealed with 100% acrylic latex
primer or paint.
Install all bu ends/joints in contact with one another.
BUTT
JOINTS
7
Never leave a gap at a
bu joint.
Do not use uncoated aluminum
or metal materials with ber
cement siding.
9
CLEARANCES
Hold back siding a minimum of 6" above nal grade.
Allow a minimum of 1"-2" above roof lines, porches, decks, etc.
Leave 1/8" gap between siding and trim surrounding
windows and doors.
Do not install ber cement
directly in contact with
surfaces that collect water.
Do not install ber cement
products ght against trim.
Use high-quality 100% acrylic latex paint or stain.
Use high-quality, exterior grade, color-matched
or paintable caulk or sealant that meets ASTM
standard C920 and is compable with both
ber cement siding and the trim materials.
Be sure to caulk wherever the siding meets the
trim, non-self-ashing penetraons, and around
all windows and doors.
If using Allura Fiber Cement Mulshake with ColorMax
nish,
please refer to the Allura Installaon Manual for best handling
and touch up pracces.
Never apply oil-based paint
or stains.
Do not caulk the boom of the
horizontal joint that is above
the “Z” ashing.
PAINTING
& CAULKING
10
DON’TsDOs
WARNING: AVOID BREATHING SILICA DUST
Allura siding products contain respirable crystalline silica, which is known to the State of California to cause cancer and is considered by IARC and NIOSH to be a cause from some occupaonal
sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and potenally fatal lung disease called silicosis, and has been linked with other diseases. Some studies
suggest smoking may increase these risks. During installaon or handling: (1) work in outdoor areas with ample venlaon; (2) use ber cement shears for cung or, where not feasible, use a
dust-reducing circular saw aached to a HEPA vacuum; (3) warn others in the immediate area; (4) wear a properly ed, NIOSH-approved dust mask or respirator (e.g. N-95) in accordance with
applicable government regulaons and manufacturer instrucons to further limit respirable silica exposures. During clean-up, use HEPA vacuums or wet methods, never dry sweep. For further
informaon, refer to our installaon guides and Material Safety Data Sheet available at www.maxile.com or by calling (800) 451-2003. FAILURE TO ADHERE TO OUR WARNINGS, MSDS,
AND INSTALLATION GUIDES MAY CAUSE SERIOUS PERSONAL INJURY OR DEATH.
Fasteners must penetrate a minimum of 1-1/4" into
structural framing.
Structural rated sheathing must be a minimum of
7/16" OSB or 1/2" plywood.
Fasteners must be proud to the surface of material.
Do not counter sink or
angle fasteners.
FASTENING
6
Use durable, non-corrosive ashing
that is non-reacve with ber cement.
There must be 1/4" clearance
between the boom of the ber
cement and horizontal ashing.
Do not use uncoated aluminum
or metal materials .
Do not caulk “Z” ashing at
horizontal openings.
FLASHING
8