Page 115 
looking for the first available channel for a new incoming call, 
you will want to configure the PBX for Descending Mode. If 
the service provider starts at the top and hunts toward lower-
numbered slots, select Ascending Mode. This parameter is 
not critical but having it properly set dramatically lowers the 
probability for a condition called glare where both the PBX 
and the Central Office attempt to put the same slot into 
service simultaneously for two unrelated calls. 
Caller ID Name 
Since most PRI lines hook directly into the international SS7 
telephone signaling network, it is possible to have parties you 
call see any Caller-ID string you desire them to see. For 
analog phone lines, your CO determines this string but for 
PRI lines, the Allworx server can determine it. Set the caller 
ID name field to the value you wish called parties to see 
when placing outgoing calls on this Digital Line.  
Note:    The service provider may override these 
settings. 
Caller ID Number 
The phone number presented to called parties for outgoing 
calls. See name setting above for more information. 
Prefer Originally Dialed 
Number (RDNIS) for display 
This causes T1/PRI originally-dialed/redirected phone 
number to be displayed on Allworx phones if the original call 
was redirected and the original call information is provided by 
the CO. 
Prefer Originally Dialed 
Number (RDNIS) for DID 
lookup/call routing 
This causes T1/PRI originally-dialed/redirected phone 
number to be used in DID routing, if the original call was 
redirected and the original call information is provided by the 
CO. 
PPP Username 
This is the login account name to use for this Digital Line 
when the line has one or more slots defined on it for data 
operation. If authentication is not required, leave this field 
blank. 
PPP Password 
This is the login account password to use for this Digital Line 
when the line has one or more slots defined on it for data 
operation. If authentication is not required, leave this field 
blank. 
PPP MTU 
Determine the Maximum Transmit Unit Size to use when 
sending IP packets to the remote end. The Allworx firewall 
will force TCP connections to negotiate a MTU no larger than 
this value. Typically the default value is 1500. The normal 
Ethernet maximum will suffice however lower values may be 
required depending on the service provider. If you are having 
problems consult your data service provider for advice. If you 
are unsure of a proper value to use and are having data 
connectivity problems, a value of 512 will negatively impact 
performance, but should always work. 
PPP HDLC Fill 
Fill value to use on the data line across all slots when the 
data connection is idle between HDLC frames. Typically the 
default value of all 1’s will suffice, but a flag fill may be 
desired in AMI line mode. 