29 Overhead Paging and Zoned Paging  
The Allworx products support two related forms of Paging – Overhead Paging and 
Zoned Paging. 
Overhead Paging: This audio goes out through the LINE IN/OUT jack or terminal 
block of the associated server. If used at a site, one typically hooks the LINE IN/OUT 
jack or terminal block to a paging amplifier or some sort of Public Address 
Announcement system. 
Zoned Paging:  This audio typically emits from a selected set of Allworx IP phones 
through their speakerphone speakers. A zone refers to each set of phones that emit 
the same class of pages. Each station can be in any combination of zones desired. 
Additionally, any combination of zones can be assigned to the Overhead Paging circuit 
so that those pages also play their audio out to the LINE IN/OUT jack or terminal block 
as referred to above. 
Allworx systems support 10 paging zones via a single paging circuit. For this reason, 
only a single zone can have an active page at any one instant in time. Users 
attempting to place a page while another page is in progress will hear a fast busy. 
29.1 Paging Amplifier and Door Release Relay 
Allworx servers have an internal relay that controls a door release mechanism. This 
makes it possible to dial a phone extension to enable someone entry to a secured 
area. The relay contacts are available via the DB-9 connector (9-pin D shell serial type 
connector) or terminal block on the Allworx server. See the server’s installation 
instructions for details. 
When using the LINE IN/OUT jack, the relay operation mode must be configured on 
the Phone System > Paging. Go to the Paging Amplifier section, and click the Modify 
link to open the configuration page. The relay operation mode can be set exclusively to 
one of the following modes: 
•  Door Entry System – users can remotely activate a door entry system to enable 
access by dialing extension 403†. The relay is active for the duration of the 
phone call or five (5) seconds, whichever is shorter. 
•  Paging Amplifier –the paging amplifier system will automatically activate 
immediately preceding each overhead page and then turn back off once the page 
completes. 
•  Unconnected –completely disables the relay and it will not operate through either 
mechanism. 
†
 Extensions may vary per system. If you are using a non-default Internal Dial Plan, consult the 
Phone Features tab of the My Allworx Manager page to determine what extensions are being 