Owner’s Manual - Storm SLGR 1600X Dehumidifier Installation, Operation & Service Instructions Alorair Solutions INC. Add: 2048 E. Francis St Ontario CA 91761 Tel: 1-888-990-7469 E-mail: sales@alorair.
Table of Contents Safety Instructions 1 Identification 1 Electrical Supply 1 How the Strom LGR 1600X Works 2 Guidelines 2 Parts Diagram 3 Using the Display-Main Screen 4 Using the Display- Submenus 6 Maintenance Instructions 8 Error Codes 9 Troubleshooting 10 Dehumidifier Storage 10 Warranty 11
Safety Instructions Don't adjust or alter the unit in any way. The use of unauthorized parts will void your warranty. Contact your approved distributor for assistance. Always unplug the unit prior to removing the cover. Inspect the power cord prior to use and do not use if it is damaged. The unit should only be used with a 115V/60Hz circuit protected by a GFCI outlet. Identification Prior to installation of the unit,write down the serial number and date of purchase.
How the Storm SLGR 1600X Works The Storm SLGR 1600X dehumidifier utilizes its integral humidistat to monitor the conditioned space. Once conditions are outside the desired setpoint, the compresser energizes and air is drawn across an evaporator coil. The evaporator coil is cooler than the dew point of the air so the water vapor will turns into liquid condensation. The air is then reheated through the condenser coil and distributed back into the room.
Parts Diagram Power line Control Panel Condensate Drain Line Quick Connect Air Filter Handle Air inlet Temp/RH sensor
Control Panel Guide Power Button Use this button to turn the dehumidifier on and off. You can also press this button while on a sub-menu if you wish to return to the main screen. Confirm Button This button is used to confirm your selected setting, as well as set the humidity level. Each time you press the button, the humidity level will increase 5% (between 35% and 90%). The default humidity level is 50% Manual Drain Button Prior to moving or storing the machine, it is helpful to use the Manual Drain Button.
2. Setting Up the Unit Once the machine has powered on, you will see the following display: U N I T I N L E 0 0 O N T 0 0 ° C 0 H R S 0 0 % a. UNIT ON- means the unit is powered on b. 00.0HRS- describes any time the machine is running from power on to power off. It includes defrosting time, but does not include the standby time once the set point is reached. The working time can be reset using the sub-menu. If it is never reset, the time will accumulate with a maximum time of 99.9 hours.
Using the Display- Sub-Menus 1. Job hours J O B H O U R S R E S E T ? > This screen allows you to clear the job hours. To clear the hours select "> ". This will clear the hours on the main screen, and "RESET" will no longer display on the sub menu. Once hours have accumulated, "RESET" will appear on the sub menu again. 2. Life Hours L I F E H O U R S 0 0 0 0 0 0 H R S "Life Hours" desribes the total working time of the dehumidifier. The life hours cannot be cleared. 3.
This screen is used to select your humidity setpoint. Press the ">" button to set the humidity value between 35% to 90%. Each time you press the button, it will increase 5% 6. Temperature Measurement This screen can be used to switch the temperature measurement betweenC° and ° F. Press the > button to switch between the two measurements. U N I T S T E M P ° C > 7. Language From this screen, you can choose your preferred language. Press the (>) button to switch between German, Spanish, and English.
Before Use Maintenance Instructions Check the power cord for signs of damage such as fraying. Replace the cord before use if there is any damage. Check the filter for signs of dirt or obstructions. Clean or replace the filter as necessary Check the coils for signs of buildup. Clean if needed. Cleaning the Machine Body Use a soft, damp cloth to clean the exterior of the unit. Do not use any soap or solvents. Filter Maintenance 1. Unplug the unit. 2. Slide out the filter. 3.
Error Codes If there is an issue with the dehumidifier, one of the following error codes will appear: E 1 L 0 H I E 5 E 4 E1 Error An E1 error code will appear if the humidity sensor has an error. The unit will not work with an E1 code, however, you can still use the manual pump button LO Error A LO error code will appear if the temperature sensor detects the incoming air is below the operating temperature range (2°).
Troubleshooting Symptom Display is Blank No Airflow Error Code:E1 Poor Connection Error Code:HI E5 Error Code Verify that both ends of the Power cord are plugged in Power Outage Reset power Filter is Dirty Clean the filter Air lnlet or OutletisBlocked Clear the blockage HumiditySensoror Communication Error Check to ensure that the sensor wire is connected at both ends. if no issues are visible, the sensor may be faulty.
Limited Warranty All warranty benefits apply to the original owner only. Warranty cannot be transferred or assigned. 1 YEAR (FROM DATE OF PURCHASE): Alorair Solitions warrants the dehumidifier will operate free of defects in workmanship and materials.
Exclusions: DAMAGE DUE TO THE FOLLOWING IS NOT COVERED UNDER WARRANTY 1. ACTS OF NATURE- INCLUDING BUT NOT LIMITED TO: FLOODING FIRE WATER DAMAGE HURRICANE/STORM DAMAGE 2. IMPROPER USAGE-INCLUDING BUT NOT LIMITED TO: POOL/SPA/TUB APPLICATIONS MISUSE, ABUSE, OR TAMPERING WHETHER INTENTIONAL OR ACCIDENTAL IMPROPER INSTALLATION OR DESIGN IMPROPER VOLTAGE LACK OF NORMAL CARE FAILURE TO FOLLOW INSTRUCTIONS 3. CORROSION 4. FREEZING 5. ANY ADDITIONAL COSTS DUE TO CHANGES IN LAWS OR BUILDING CODES 6.