Datasheet
Chapter 3: Installation
Pulsed mode operation
1. connect the CPL cable to the LDD
2. connect the LDD to the TPG:
a) using the CPL Lemo 00 +12VDC cable for power supply of the LDD
b) using the CPL BNC cable into the Out1 and Out2 output
IMPORTANT:
The LDD ground must be floating.
3. connect the LDD to the external power supply using the CPL red and black
banana cables
4. if no bias-T external circuit is to be used, shortcut the signal (yellow) and ground
(black) banana cables by connecting them together. See section B.3 for details
on bias-T control
• LLH housing in pulsed mode:
1. connect the LLH to the TCU using the CTL cable
2. connect the LLH to the LDD using the low impedance line LBI
3. if available, connect the cooling water tubing to the corresponding connec-
tors of the LLH
Note: if no water cooling is being used, carefully monitor the LLH module
case temperature. Air cooling and heat dissipation must be provided.
CAUTION:
If the LLH module case exceeds a temperature of 60
◦
C, permanent
damage to the laser chip may occur.
• HHL housing in pulsed mode:
1. connect the HHL to the TCU using the CTLm
2. connect the HHL to the LDD using the low impedance line LBI via the
CTLm cable
40 QCL user’s manual v3.0