User's Manual

ALPHA 9500 Interim OPERATING MANUAL
www.alpharadioproducts.com
22
4.2.3.2 High Voltage Connection
Connect the transformer to the 7-pin
connector on the high voltage board (the
lower of the two pictured boards).
1
Locate the 7-
pin connector
coming from
the transformer.
2
Carefully route the
high voltage (HV)
line below all of
the other bundled
wires taking care
to not bump or
bend components
on either board.
Also make sure
the HV wiring
doesn’t touch
any of the upper
circuit board.
3
Align the HV
connector,
making sure
that all pins
are in their
appropriate
slots.
4
Gently but
firmly push
the connec-
tor together,
ensuring that
it is properly
mated.
This is the
mains connec-
tor, move it
out of the way
while working
with the HV
connection