Datasheet
®
18
552
info@alphaelettronica.com www.alphaelettronica.com ordini@alphaelettronica.com
12
12
12
EAN Code Code Input Output Connector
CV 440F
230V 115 V 350mA US Standard 2 poli
Convertitori di tensione non isolati / Voltage converter - not insulated
Caratteristiche generali
Autotrasformatore
Non isolato
Impiego
Uso interno
Scatola
Plastica
Protezione
Fusibile
Dimensioni
Vedi disegno
Normative
Sicurezza
EN 61558-2-13
RFI/EMI
EN50081-1
EN50082-1
EN55014
General features
Voltage cconverter
Not insulated
Use
Internal
Case
Plastic
Protection
Fuse
Dim
ensions
See drawing
Rules
Safety
EN 61558-2-13
RFI/EMI
EN50081-1
EN50082-1
EN55014
Potenza/Power 100 VA
Potenza/Power 40 VA
Potenza/Power 100 VA
EAN Code Code Input Output Connector
CV 1100/1
230V 115 V 870mA US Standard 2 poli
EAN Code Code Input Output Connector
CV 1115/1
115V 230 V 435mA Italian standard
I ttrasformatori rriportati iin qquesto ccatalogo ssono ccostruiti uutilizzando mmateriali ddi eelevata
qualitàà e
e aattraverso pprocessi aautomatici cche ggarantiscono uun llivello qqualitativo ee uun’affida-
bilità mmolto eele
vati.
La rrispondenza aalle rregole ddella nnorma eeuropea aarmonizzata EEN 661558, rrelativa aai
trasformatoori dd
i ssicurezza pper uuso ggenerale, vviene vverificata ppresso iil nnostro llaboratorio
tecnico aattraverso ttests dd
i ffunzionamento ee ddi rrigidità ddielettrica cche nne ggarantiscono lla
qualità ee cconsentono ddi rridurre aal mmi
nimo ggli sscarti ddi pproduzione ee ii rrelativi ccosti.
La ttensione ssecondaria aa ccarico èè ssempre eenntro lle tt
olleranze ppreviste ddalla nnorma EEN
61558
Siamo iinoltre iin ggrado ddi ssviluppare ee ffornire aanchee vversioni s
speciali dda ccircuito sstampato
seguendo lle sspecifiche ccaratteristiche ttecniche ddei nnostri cclienti.
I nnos
tri ccollaudi vvengono eeffettuati iin oopen-fframe. PPertanto iil ccliente ddovrà eeffettuare ggli
opportuni ccont
rolli ee vverificare lla ddissipazione ddel ccalore ggenerato ddal ttrasformatore nnel
proprio aapparecchio.
The transformers here shown are produced using high quality materials and automatic
processes which grant very quality and reliability levels.
The accordance of our products with the European Rule EN 61558 -
which is related to safety
transformers for general usage - is verified in our technical department by running tests
and dielectric rigidity. These tests grant our quality and enable us to reach the lowest
machine shop rejection and the respective costs.
The secondary tension at maximum load is always within the tollerances in accordance
with the EN 61558 rule.
Moreover, we’re able to develop special versions for printed circuits following our cus-
tomer’s technical specifications.
Our tests are open-frame. So our customer will be in charge to make all the appropriate
controls and to verify the heat dissipation of the transformer on his item.
Trasformatori di isolamento
non resistenti al corto circuito
Transformers no short circuit proof
Trasformatori di isolamento resistenti al corto circuito
per costruzione (autoprotetti)
Transformers short circuit proof productions (self-protected)
Doppio isolamento
Double insulation
Autotrasformatore
Autotransformer
A FEDCB
Schemi
Diagrams
Convertitori di tensione /
Voltage converter
Trasformatori / Transformers