Specifications

29
We reserve the right to modify technical specifications without prior notice.
83053100bUK © Alpha-InnoTec GmbH
Commissioning
Proceed as follows:
Conduct a thorough installation inspection and go
through the items on the general checklist.
“General checklist.
The installation inspection will prevent damage
to the heat pump system that could be caused by
incorrect installation work.
Make sure of the following
Clockwise rotary eld of the load power
supply (compressor).
Installation and assembly of the heat pump
according to the information in this operating
manual.
All electric installation work must be properly
completed.
A 3-pole automatic circuit-breaker must
be installed for the compressor. It must have a
contact gap of at least 3 mm.
The heating circuit must be rinsed, lled and
thoroughly bled.
All valves and shut-off devices of the heating
circuit must be open.
All pipe systems and components of the system
must be sealed.
Carefully ll out and sign the completion report for
heat pump systems…
“Completion report for heat pump systems”.
In Germany and Austria:
Send completion report for heat pump systems
and general checklist to the manufacturer’s factory
customer service department.
In other countries:
Send completion report for heat pump systems
and general checklist to the manufacturer’s local
partner.
Overview “Customer service”.
The heat pump system will be commissioned by
customer service personnel authorized by the
manufacturer. There is a fee for commissioning!
The initial lling and commissioning of the hot water
tank must be carried out by a qualied technician.
Make sure of the following
The water supply to the hot water tank must be
open.
The hot water tank must be lled.
If the heat pump is switched on with an empty
tank, the control element will indicate a malfunc-
tion.
Operating manual of the heating and heat pump
regulator.
safety temperature limiter
A safety temperature limiter is built into the electric
heating element. In the event of a malfunction in the heat
pump or air in the system, check whether the reset but-
ton of the safety temperature limiter has tripped. If this
is the case, push in the button.
1 Safety temperature button on
electric heating element
2 Reset button