opening the angle ball valves on the module box
Open all angle ball valves on the module box by turning
them 90° counter-clockwise.
safety component
The safety component for the heating circuit is in the extra
box.
Mount the safety component on the connection provided
on the top of the unit.
expansion vessels
The expansion vessel of the heat source is included in deli-
very and must be installed with the connection assembly.
The expansion vessel for the heating circuit, the correspon-
ding cap valve and the wall mount are included in the scope
of delivery. They must be integrated in the heating circuit
on-site in compliance with the applicable standards and di-
rectives.
We recommend installing a suitable expansion vessel (not
included in delivery) in the hot water circuit. This equalizes
pressure fluctuations or water shocks in the cold water net-
work and prevents unnecessary loss of water.