Specifications

24
We reserve the right to modify technical specifications without prior notice.
UK830301/170306 © Alpha-InnoTec GmbH
Adjust mixing valve.
Use the wrench included in the scope of delivery.
Alternatively: Use a size 6 Allen wrench.
Insert wrench in the servo-motor.
Turn wrench counter-clockwise until the regulator
of the servo-motor is at 0%.
Switch on the circulating pump of the heat source
and allow to run.
After 2 minutes, with the circulating pump running,
turn wrench clockwise until the regulator of the
servo-motor is at 100%.
Leave at this setting for 2 minutes.
With the circulating pump running, turn wrench
counter-clockwise until the regulator of the servo-
motor is at 50%.
Turning the regulator to 50% means an even mix
-
ture in the 3-way mixing valve from A and B to AB.
Reset servo-motor of the mixing valve to automatic
as soon as bleeding is completed.
NOTICE.
Push switch on the bottom of the servo-
motor forward.
For units with cooling function, an additional bleeding valve
is installed above the servo-motor for the heat source.