Specifications

29
We reserve the right to modify technical specifications without prior notice.
UK830301/170306 © Alpha-InnoTec GmbH
Dismantling
DANGER!
Danger of fatal injury due to electric current!
Disconnect unit from power supply before
dismantling!
DANGER!
Only qualied electrical technicians are allo-
wed to disconnect the unit from the power
supply and de-install all electrical connec-
tions.
DANGER!
Only qualied heating or cooling system
technicians are allowed to remove the unit
from the system.
CAUTION.
The anti-freeze mixture of the heat source
must not be allowed to enter the sewer system.
Collect anti-freeze mixture and dispose of
properly.
DANGER!
Only qualied cooling system technicians are
allowed to dismantle the unit and its compo-
nents.
CAUTION.
Recycle or provide for proper disposal of
unit components, refrigerants and oil in ac-
cordance with the applicable regulations,
standards and directives.
removal of the buffer battery
CAUTION.
Before scrapping the heating and heat pump
regulator, remove the buffer battery on the
processor board. The battery can be remo-
ved using a side cutter. Dispose of battery
and electronic components in keeping with
environmental considerations.
removal of the module box
Remove insulation.
Close angle ball valves.
Attach service hoses from the extra box to the
angle ball valves.
Open bleeding valves of the angle ball valves using
a bleeding key and completely empty the module
box.
Disconnect hydraulic and electric connections.
Raise module box using the straps and lift and pull
from the unit.