User guide

Autostart (Automatic Connection)
To enable the hostlist:
1) Enter a Connect Mode of 0x20 (2X), where X is any digit. The menu shows you
2) A list of current entries already defined in the product.
3) To delete, modify, or add an entry, select Yes. If you enter an IP address of 0.0.0.0, that entry and all
others after it are deleted.
4) After completing the hostlist, repeat the previous step if necessary to edit the hostlist again.
5) For Retrycounter, enter the number of times the Lantronix unit should try to make a good network
connection to a hostlist entry that it has successfully ARPed. The range is 1-15, with the default set to 3.
6) For Retrytimeout, enter the number of seconds the unit should wait before failing an attempted connection.
The time is stored as units of milliseconds in the range of 1-65535. The default is 250.
Datagram Type