Manual

18
042-288-B0-001, Rev. A
1.0 System Overview, continued
1.5 Speci cations
Model CE-3x2 5.0kW
PN-6x-T 7.5kW
DC Output Voltage: -51.5 to -52V @ no load -51.5 to -52V @ no load
DC Output Load Regulation: 0.5V 0.5V
Output Current: 52V @96A max. 52V @ 144A max.
Noise
Voiceband: <54dBrnc <54dBrnc
Wideband: <100mVrms in any 3kHz bandwidth from 10k to 20mHz <100mVrms in any 3kHz bandwidth from 10k to 20mHz
Broadband: <250mVp-p from 20 to 100mHz <250mVp-p from 20 to 100mHz
Engine: 398cc, air-cooled, single OHV
10.5hp (using natural gas fuel)
624cc, air-cooled, twin OHV
13.1hp (using natural gas fuel)
RPM (Variable Speed): 2800 to 3600RPM 2100 to 3450RPM
Acoustic Noise
dBA 10' @ 100% rated load: 68.5 avg. 70.3 avg.
dBA 20' @ 100% rated load: 62.5 avg. 64.3 avg.
dBA 10' @ 70% rated load: 66.9 avg. 66.4 avg.
dBA 20' @ 70% rated load: 60.9 avg. 60.4 avg.
System Size: CE-3x PN-6x
Height (in/cm): 44/111.8 36/99.1
Width (in/cm): 26/66 39.25/99.7
Depth (in/cm): 24/61 24/61
Weight (lb/kg): 395/179.2 338/153.3
Fuel Consumption
Natural Gas: 1000BTU/ft
3
80ft
3
/hr 156ft
3
/hr
Propane Gas: 2520 BTU/ft
3
1.1gal/hr 1.48gal/hr
40ft
3
/hr 54ft
3
/hr
4.62lb/hr 6.24lb/hr
Gas Inlet Pressure: 0.5 to 2 PSI Inlet pressure
(Please contact Alpha Technologies for low pressure)
0.5 to 2 PSI Inlet pressure
(Please contact Alpha Technologies for low pressure)
Ignition Charger Voltage: 13.5Vdc 13.5Vdc
Ignition Charger Current: 6A max. 6A max
Remote Interface Length: 50ft. max
Distance depends upon proper installation, de-rating,
and wire gauge. Please contact Alpha Technologies for
remote interface length usage.
25ft. max
Distance depends upon proper installation, de-rating, and
wire gauge. Please contact Alpha Technologies for remote
interface length usage.
Agency Compliance: UL2200, NFPA 37/54/58 and 70, CSA 22.2, FCC Class A UL2200, NFPA 37/54/58 and 70, CSA 22.2, FCC Class A
Common to All Models
Fuel System, Controls & Monitoring: The controls and fuel system meet applicable sections of NFPA 37, 54, and 58 for automatic unattended operation of
remotely located generators. Full system control and status monitoring included
Sensors: Gas hazard, pad shear, water intrusion & tamper
Safety shutdowns: Low oil pressure
Water intrusion
Pad shear
Gas hazard (propane or Natural Gas)
Over speed
Over crank
Over temp
Low fuel pressure shutdown (Propane only
)
Optional Features
Optional Integrated Propane
Storage: (5kW APU only)
For locations where gas is not available, Alpha offers the CE-G propane enclosure for use with the 5kW APU system.
Contact local propane supplier for proper tank sizing. Fully CSA & NFPA compliant, and designed for curbside
applications.