Instruction Manual

15
016-559-B0-001 Rev. A
Fig. 2-7, Visible Center Conductor of Installed
Connector
Fig. 2-6, Seizure Connector
2.0 Installation, continued
2.5 Coaxial Cable Attachment
Tools Required:
5/8” socket wrench with 6” extension
20-200 in-lb torque wrench
Procedure:
1. Remove the two seizure connectors from
the enclosure.
Verify center conductor is centered in the groove in
the plastic base.
NOTE:
2. Insert the prepared coaxial connector into
the desired port (1-input; 2-output) and
torque to 180 in-lbs.
3. Replace the seizure connectors and
torque to 90 in-lbs.