Dear customer Congratulation to your purchase of “BRAVE SMYLE door intercom”. The BRAVE Smyle door intercom is designed as universal project to be suitable for different installation on the field and brings more features and possibilities.
Content 1 BASIC DESCRIPTION ......................................................................................... 6 1.1 1.2 1.3 1.4 1.5 2 FEATURES ........................................................................................................ 6 TERMINOLOGY ................................................................................................. 7 DIFFERENT MODELS OF SMYLE BRAVE DOOR INTERCOM ................................ 8 MODELS OF BRAVE DOOR INTERCOM ............................
.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 6 TECHNICAL PARAMETRES .......................................................................... 51 6.1 6.2 7 BASIC PARAMETRES ....................................................................................... 34 TIME PARAMETRES......................................................................................... 36 SYSTEM PARAMETRES .................................................................................... 39 HANDSFREE PARAMETRES SETTING ..............
1 BASIC DESCRIPTION 1.
1.2 Terminology Telephone line analog (2 wires) is way of connection to public network (PSTN line) or connection to PABX – telephone exchange at place of installation ( extension line) Line picking up begin of call – same like OFF HOOK by handset Line hanging up end of call – same like ON HOOK by handset Dial DTMF - tone dial. It is dial by 2 tones combination (dial also special character * and #.
1.3 Different Models of Smyle Brave door intercom Brave door intercoms is designed as new generation of door intercom units reflects all experiences collected during last 10 years of succesfull sales of door enry solutions. Features and parametres are different for different models of intercom to provide best balance between price and usage value.
1.5 PCB Schematics All functional and connectional elements are marked by red rounded number at bellow picture. Explanation follow on next page. Pict.
1. Camera lighting - infra LED. It lights up space before camera when is active. It is possible switch off (via. item 7) – version for camera only /C 2. Connector to PC connection via USB cable 3. Analog colour camera – version with camera /C only 4. Speaker connection 5. Microphone connection (caution on polarity) 6. DIP switch in all models: 1 = Service, usage – when programming password is forgotton. Incoming call is going directly to programming mode where you can set new password.
You can also use 24V DC power supply. It is useful mainly at installations where power supply is already installed and it is used for sliding doors, RFID, etc.. The heating has control element to restrict power. The remaining components are designed for voltage up 24V DC!!! It not depends on polarity.
2 Installation 2.1 Assembly 2.1.
2.1.2 Assembly of cards backlighting 2.1.3 Wall mounting of Brave Smyle Make the mounting by attached pack with screws and plug (drill 5mm).
2.1.4 Replacing of cards backlighting after wall mounting 2.1.5 Cards exchange (name cards) Every button has own card ( label) holded by plastic flag ( via picture). You can print out paper labels from special Excel file (downloadable on www.alphatech.cz or ).
2.2 Connection The basic functionality of intercom (voice communication) needs connection of telephone line only - LINE (8) on .Pict. 1 Brave Smyle. The line is connected by 2 wires (a,b) and in stand by has usually voltage 24V - 60V, short circuit current 20mA - 60mA. When line is OFF HOOK the line voltage is 7V - 10V. Line connection Brave Smyle intercom announce by sound signal (Reset) ♫ (capture 3.1 page.21) when is disconnected from line certain time.
Relays connection examples are mentiond on following page. It is not all of them but give you an idea how should be connected individual circuits (red rings with numbers = example numbers). 1. Basic connection - 2 elektrical locks and possibility independently control two doors. (relay mode 1 and 2 m=1) or progressive door opening (relay mode 2 m=5 - version (C) only. 2. Two power supply – possibility to use independently two power supply One for Brave Smyle and second for electrical locks.
Pict.
2.3 Camera ( /C version only) Technical parametres: - videonorm: - sensor: - picture area: - resolution: - video output: - automatic profit control: - minimal lighting: - automatic lens shutter: - camera view: - zoom: 18 PAL-CCIR CMOS 1/3'' 5,78x4,19mm 628x582pixel 380 rows 1V p-p/75 ohm 18dB 3LUX 1/60-1/15000sekund 50st.
2.4 Accssesories 2.4.1 Weather hood It increases intercom protection during raining. It is fixed by adhesive labels from sides. 2.4.2 TimeRelay Time relay allows expansion of relays functionality. It is individual product and detail manual you find on our websites www.alphatech.cz 2.4.3 DistyBox This optional modul is plastic box allows you to connect analog unit (phone, intercom) into wireless system DECT – GAP (for example Siemens line GigaSet, TopCom line Butler etc.).
2.4.4 Power supply 12V As standard we provide for Brave Smyle intercom AC power supply 12V/1A . It is not part of unit packaging. It must be ordered individualy. More info about electrical locks and power supply on www.alphatech.cz. 2.4.5 Programming cable USB USB cable is not part of packaging. It must be ordered individualy. USB drivers are downloadable on www.alphatech.cz 2.4.6 BlackBox BlackBox is DTMF modem useful for remote programming from PC.
3 Door intercom service Functionality of Brave Smyle door inercom is adjustable by parametres settings (via. Programming parametres capture page 26). 3.1 Signalling overview The Brave Smyle door intercom signalling acoustically stages which are happening during operation. Samples of acoustical sounds you can play in BraveSet ( PC programm).
3.2 Visitor at the door Door intercom buttons have signs (cards) like usual ring buttons. Visitor find desired name (for example“Scott") and push it. The Brave intercom pick up the line and "play" tone line pick up (when is not switch off by par.62) and dial phone number saved under the button (parametr 1 or 2 up door intercom mode). From Brave intercom speaker you hear ringing tone and phone of Mr. Scott is ringing. As soon as Mr. Scott pick up ringing phone he can talk to visitor at the door.
mode m = 1 Action Evaluation of correct external code from buttons (parametr 3111 and 3121) Note According settings DAY/NIGHT According settings DAY/NIGHT According settings DAY/NIGHT According settins DAY/NIGHT Internal code from phone Parametr Relay 3211-3215 3311-3315 3411-3415 3221-3225 3321-3325 3421-3425 321* 331* 341* 322* 332* 342* 351 You can dial 1 or 2 numbers of code 2digits code is default You can shorter it by using * on first digit of code during programming 352 361 362 Mode m = 5 Ac
mode m = 4 Action Note Button push Parametr Relay 3114 Any button different from 311* or 312* 3124 3114 Button setup by 311* or 312* 3124 Mode m = 6 Action Button push Note Any button different from 311* or 312* Parametr Relay 3116 - 3126 - 3116 Button setup by 311* or 312* 3126 Poznámka: t1 – time activation 1 of relay (parametr 371) t2 – time between pulses 1 of relay (parametr 301) t3 – time between activation 1 and 2 relay (parametr 39) t4 – time activation 2 of relay (parametr 372) t5 – t
3.3.2 Incoming call Incoming call is a call into door intercom (generated by person inside the building). After dialling extension number where is connected door intercom the door interocm line is ringing. After setup number of rings the door intercom picks up (parametr 51) and you can talk. Other possibilities are the same like in case of outgoing call (capture 3.3.1). First exception is first 10sec where you can dial "# and service password" (parametr 44).
4 Parametres programming 4.1 Programming by phone 4.1.1 Programming enter You can enter programming mode by following ways: 1. password – incoming call only! – pick up the phone and dial phone number where is door intercom connected (either extension number when door intercom is connected to PBX or PSTN line number of building where is door intercom installed and let operator connect you to appropriate door intercom extension). Door intercom picks up (you hear pick up acoustic tone – via. capture 3.1 page.
4.2 PC programming – BraveSet programm For PC programming of door intercom you have to purchase special USB cable USB-KAB and programm BraveSet ( free on every CD). Then you have to connect door intercom into the line or at version /C or (C) switched ON and connected power supply 12V - DIP3 and 4. Procedure: - Connect telephone line into door intercom or at version /C and (C) you can use external power supply 12V (DIP 3,4) - Connect special USB cable to PC USB socket .
5 Descriprion of programmable parametres Parametres always starts by fix, mandatory part ( adress) and variable part – it is your dial. Range and explanation is always under each table . All is dial like it is written in table. You dont dial any confirmation character. After savings into memory you get back confirmation tone. When dialled value is incorrect you get immediatelly error tone. 5.
Settings examples: 1. first button should dial at DAY number 358 and in NIGHT 0_603441296 , you programm it - 101358 and wait for ♫, next 2010 *0 603441296 and wait for ♫ 2. second button should dial at DAY and NIGHT 123#1*2Flash3, you programm 102123#1 ** 2 *# 3 and wait for ♫, next 202123#1 ** 2 *# 3 and wait for ♫ Note. When you dont use mode of 2 group numbers or DAY/NIGHT mode we recommend setup DAY/NIGHT mode (parametr 47) and next setup same code for DAY/NIGHT switching (parametry 45 and 46).
m=7 permanent closing / opening – usable at versions /C and (C) only, if switching (DIP 3,4)+par.64. By command for pulse 1 is closed and for pulses2 is opened. This stage stays in door intercom even after power/line disconnection. This mode you can use for potting, glasshouse opening, heating activation etc.. m=8 activated up DAY/NIGHT mode settings - usable at versions /C and (C) only, if switching (DIP 3,4)+par.64. Version /C allows copying manual DAY/NIGHT switching only.
Caution on numbers identity of password. When one password includes other, for example:password for relay1 is 1234 and for relay 2 12345, then always after pushing button 4 relay 1 will be activated and relay 2 wont be never acivated. When you select password for relay 2 234, then after button 4 pushing both relays will be activated. Note1. switching to DAY/NIGHT mode stays setup in door intercom even after power (line) disconnection.
Example: command to activate relay1 with 1 pulse *8, command to hang up *8 and command for activation relay2 with 2 pulses *9. Dial: 352*8 ♫ , 432*8 ♫ , 362*9 ♫. You are in communication with door intercom unit. Dial command for open sliding gate 9. First pulse starts sliding the gate and second pulse stop it. The size of spot for person entrance is according time between each pulses (parametr 30). After person etnering you dial 8. The door intercom makes one pulse and hang up. Sliding gate is closing.
Parametr Value 3#0 p Description p = 1 enabled / disabled p = 0 connection code relay COSW (0/1) Default 0 p – turns on transmission serial code to activate the first switch. CAUTION - at activation this function never connect to the circuit electric lock without board COSW - code relay - threatens to destroy the relay in Brave communicator! The following codes may be the same or different for the resolution switching on multiple parallel connected relay code.
5.
Parametr Value 45 dd 46 nn Description Default Command to switch into DAY mode (00-99,*0-*9) Command to switch into NIGHT mode (0099,*0-*9) 11 10 1 dd – command to switch into DAY mode [2 digits] / 1 nn – command to switch into NIGHT mode [2 digits] / 1 / - command has always 2 digits but if you want use 1 digit then you have possibility insert " *a " where a is just one number which switch DAY/NIGHT mode (star represents empty character and must be on first position). Note.
5.4 Time parametres Parametr 51 Value q Description Default Number of rings before door intercom picks up incoming call (1-9) 2 q – number of incoming call rings . Door intercom picks up between rings and 2 sec after detection of q – th rings. Number is adjustable from 1 to 9. Parametr 52 Value d Description Maximal call duration Default d – maximal time for which door intercom is OFF HOOK. This time you can prolong by dial character during a call by phone (* or # - parametr 42).
Parametr 54 Value z Description Hanging up time during REDIAL Default 2 (1-5) z – time [sec] for which door intercom hangs up before pick up for REDIAL (button push during call, busy tone detection) [range 1-5] Parametr 55 Value z Description Time before start dialling Default 1 (1-5) z – time [sec] after door intercom picks up and before start dialling [range 1-5]. This time is different for every PBX but usually all PBXs accepts dial within 2 seconds after line is picked up.
Time of tone duration DTMF (tone) dial (04-16) Time of space duration between DTMF tones (04-16) 503 tt 504 mm 505 f Time of Flash duration 506 p Time of pause duration / pause between numbers (1-0) (1-6) 10 (100ms) 10 (100ms) 1 (100ms) 4 (800ms) –Time of tone duration DTMF (tone) dial is calculated up: (inserted number) x 10 = tone duration time [ms] [range 04-16 tj.
5.5 System parametres Parametr 61 Value z Description Acoustic signalling (confirmation, error, empty memory, call termination...) (0/1) Default 1 In default the stages of door intercom are acoustically signalling. By parametr „z“ you can switch off this signalling. Possible values are z=0 – signalling is off z=1 – signalling is on Parametr 62 Value v Description Acoustic signalling off hook/on hook (0/1/2) Default 1 In default is signalling pick up and hang up of the line.
Parametr 65 Value z description Default 0 Acustic signalling of relay activation (0/1) In default the activation is off z=0. Usually you can use this fetaure for DC power supply 12V. Then when el.lock is released you dont hear „buzzing“ so visitor doesnt know that el.lock is released. When you activate this feature z=1 then during relay activation you hear special sounds simulating relay activation. Note.1 This feature is available for relay mode m=1, m=5 only. Note.
5.6 HandsFree parametres setting Parametr Value 71 gg 72 ff 73 rr Description Default Reception loudness 01-16 (16 is highest) (SPK) Transmission loudness 01-16 (16 is highest) (MIC) Speaker loudness 01-16 (16 is highest) (TRH) 07 07 07 gg / ff / rr – numbers are inserted always by 2 digits in range [01-16] After reception of confirmation ♫ is new value immediatelly active and you can test it.
Parametr 76 Value b Description Default 2 Level of microphone start 1-4 (4 is highest) On the line is simultaneously signal from microphone and speaker. In handsfree circuit is a few functional blocks to suppress acoustic shock. The basic one is circuit of semiduplex operation when incoming signal decrease microphone amplificatio as same as signal from microphone decrease incoming signal. The level of microphone start is setup by this parametr.. As lower value as higher microphone sensitivity is.
Parametr Value 79 k Description Compemsation of wires losses depends on line current (0/1/2) Default 1 Door intercom Brave includes circuit which during long distance installations (100m and more from PBX) can compensate losses on wiring. In default the feature is off k=0. You can setup in two levels depending on line current of PBX (short circuit current I0).
5.7 Time programm – automatic DAY/NIGHT switching (C) (C) version only ! Parametr Value 09 a Description Default ON / OFF automatic DAY/NIGHT switching and setting time control (0/1/#) 0 When door intercom Brave includes RTC circuit - (C) version then you can activate automatical switching from real time a=1. The condition is correct time settings. You can verify it easily by diallingu a=# and door intercom reply either by confirmation tone (all is correct) or error tone (you have to setup the time).
Parametr Value Description Default sunday – time setting hours hh and minutes 00 hhnnkkjj nn starts day and hours kk and minutes jj 01 hhnnkkjj 02 hhnnkkjj 03 hhnnkkjj 04 hhnnkkjj 05 hhnnkkjj 06 hhnnkkjj 07 # starts night monday - time setting hours hh and minutes nn starts day and hours kk and minutes jj starts night tuesday - time setting hours hh and minutes nn starts day and hours kk and minutes jj starts night wednesday - time setting hours hh and minutes nn starts day and hours kk
5.8 Default settting and erasing Parametr 8# Value # Description Default execute Default This setting doesnt change parametres 1 and 2 (numbers saved in memories) Parametr Value Description Default Erase all numbers in group 1 (Day mode) Erase all numbers in group 2 (Night mode) 81 82 83 Default settings for parametres 3x only 3 only.. 84 Default settings for parametres 4x only 4 only.. 85 Default settings for parametres 5x only 5 only..
5.10 Parametr Parametres overview Value Description Default 1 tt nn… number nn under button tt - 2 tt nn… number nn under button tt - 31 rm relay r works in mode m 31 r* tt 32 rp hh... 33 rp hh... 34 rp hh...
43 g bb Command to hang up door intercom by phone (00-99,*0-*9) 44 xxxx Service password (0000-9999) 0000 45 dd Command to switch into DAY (00-99,*0-*9) 11 46 nn Command switch into NIGHT (0099,*0-*9) 10 47 e (0/1) 1 Door intercom dial mode 155 266 Feature of line hanging up by again push of the same button (0/1) Number of rings before door intercom pick up incoming call (1-9) 4* k 51 q 52 d Maximal call duration 53 w 54 1 2 (0-9,*,#) 2 Time between button push (1-
Depression of DTMF reception from microphone (0/1) BabyCall – call without neccessity to insert phone number (0/1) Delay start for PBX´s with extension test (Siemens) (0/1) Reception loudness 01-16 (16 is highest) (SPK) Transmission loudness 01-16 (16 is highest) (MIC) Speaker loudness 01-16 (16 is highest) (TRH) 66 i 67 b 6* t 71 gg 72 ff 73 rr 74 c Soft pass of switching (0/1) 1 75 n Depression of background sound (0/1) 1 76 b Level of microphone start 1-4 (4 is highest) 77 s 7
starts night saturday - time setting hours hh and 06 hhnnkkjj minutes nn starts day and hours kk and 07 # 8# # execute default Erase all numbers in group 1 (DAY mode) Erase all numbers in group 2 (NIGHT mode) 81 82 83 Default setting for parametres 3x only 3 only.. 84 Default setting for parametres 4x only 4 only.. 85 Default setting for parametres 5x only 5 only.. 86 Default setting for parametres 6x only 6 only.. 87 Default setting for parametres 7x only 7 only..
6 Technical parametres 6.
7 Table for easy programming Into empty parts of table write values which you desire to programm. In double linked part are mentioned programming commands for easy programming. Moreover the programmed values stay in manual for future changes. Description Programming sequence digits description detail par.
password relay 1 (1pulse) Day/Night 3212 6 password relay 1 (1pulse) Day/Night 3213 6 password relay 1 (1pulse) Day/Night 3214 6 password relay 1 (1pulse) Day/Night 3215 6 password relay 1 (2pulses) Day/Night 321* 6 password relay 2 (1 pulse) Day/Night 3221 6 password relay 2 (1 pulse) Day/Night 3222 6 password relay 2 (1 pulse) Day/Night 3223 6 password relay 2 (1 pulse) Day/Night 3224 6 password relay 2 (1 pulse) Day/Night 3225 6 password relay 2 (2 pulses) Day/Night Day D
Button selection for relay 1 Button selection for relay 1 Relay 1 activation by phone Relay 2 activation by phone Relay 1 activation by phone Relay 2 activation by phone Time of closing for relay 1 Time of closing for relay 2 Incoming call relay1 control Incoming call relay2 control Delay between closing relay 1 and 2 Time between pulses rel 1 311* 312* 351 352 361 362 371 372 381 382 2 [sec] 39 2 [sec] 301 302 3#0 3#1 3#2 3#3 3#4 3#5 2 41 42 431 432 44 45 46 47 4* 1 51 52 53 54 55 56 500 1 m=6
Number of busy tones Time duration of permanent tone Time duration of tone dial nn x 10 Space betweeni DTMF nn x 10 tones Flash duration n x 100 pause/ space between n x100+400 numbers DTMF transmission level 04-16 501 1 502 sec 2 503 ms 2 504 ms 2 505 ms 1 506 ms 1 -dBm 2 preemphase DTMF 0/1 Listening in DTMF - level 1-4 507 508 509 Acustic signalling Acustic signalling Off hook /on hook Acustic signalling beeps 0/1 61 1 0/1 62 1 0/1 0/1 63 64 1 0/1 65 1 0 /1 66 1 0
Date setting+weekday w ddmmyyw sunday hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj Monday Tuesday Wednesday thursday friday saturday 56 082 00 01 02 03 04 05 06 7 8 8 8 8 8 8 8 BRAVE – user guide
Producer: Distributor: Sales date: © JR 2011-13 verze 2.