User guide

This test set is designed to take conductance
measurements exclusively on 6 and 12 Volt Lead/Acid
batteries while either on line (float service) or off line
Operating range:
Voltage: 5.5V – 15.0V DC
Amp Hour Range: approx. 5 Ah to 450 Ah,
Conductance: 0 – 3,200 Siemens
Test results: DC Voltage and Conductance (expressed in
Siemens) will be stored in internal memory after each test
until the next measurement. By depressing the “Review”
key, the last test result will be displayed for 15 seconds to
allow time to manually record the test information
Accuracy: +/- 2% across test range
Voltmeter resolution: +/- 20 mV DC
Calibration: Auto-calibration each test; no calibration
required
Power requirements: Unit is powered by the battery under
test; one replaceable 9V alkaline battery used to power
the display
Operating Temperature range: 0º C to +40º C, 95%
relative humidity, non-condensing
Storage Temperature Range: -29º C to + 70º C, 95%
relative humidity, non-condensing
Over Voltage Protection: Fused protected to 60 V DC
Fuse Specifications: 5mm x 20mm 1.25 Amp fuse
Reverse Polarity Protection: Diode protected
Test cables: Interchangeable interface. One standard
#C065 DuraProbe cable set and spare probe tips
provided with each tester – other interfaces available
from Alpha.
SPECIFICATIONS
BATTERY TESTING AND OPERATION
Automatic Battery Testing
The Digital Midtron Analyzer requires no setup or calibration.
Each unit is shipped with the DuraProbe cable pre-installed
and ready to test.
The Analyzer must have good contact with both the positive
and negative battery posts before it will begin to process the
test. The unit will then automatically begin upon the
establishment of a good connection.
(Continued on next page.)
®
Model: DM-3200 AT
QuicQuic
QuicQuic
Quic
k Rk R
k Rk R
k R
efef
efef
ef
erer
erer
er
ence Guideence Guide
ence Guideence Guide
ence Guide
Digital Midtron
Alpha Technologies
3767 Alpha Way
Bellingham, WA
98226
Tel: 360-647-2360
Fax:360-671-4936
www.alpha.com
Alpha Technologies
1075 Satellite Blvd., Ste. 100
Suwanee, GA 30024
Tel: 678-387-3995
Fax:678-584-9259
www.alpha.com
®
Copyright © 2003
Alpha Technologies, Inc
P/N: DM-3200 AT
DEEP CYCLE SERIES Siemens/Mhos
DCS-33 725
DCS-50SAE 850
DCS-75BT 1200
DCS-100L 1400
UPS—HIGH RATE SERIES (AGM)
UPS12-100 600
UPS12-140 950
UPS12-170 980
UPS12-200 1100
UPS12-270 1375
UPS12-310 1750
UPS12-370 1850
UPS12-475 2000
UPS6-620 4200
UPS-FLAME RETARDANT HIGH RATE SERIES
UPS12-100FR 600
UPS12-140FR 950
UPS12-170FR 980
UPS12-270FR 1375
UPS12-310FR 1750
UPS12-370FR 1850
UPS12-475FR 2000
UPS6-620FR 4200
MPS PRODUCTS (AGM)
MPS12-33 800
MPS12-50 980
MPS12-75 1200
MPS12-88 1300
MPS12-100 1400
TELECOMM—LONG DURATION SERIES (AGM)
TEL12-125 2000
TEL12-30 800
TEL12-30/SLC 800
TEL12-45 900
TEL12-45/SLC 900
TEL12-70 1125
TEL12-80 1325
TEL12-90 1590
TEL12-105F 1325
TEL6-180
ALPHACELL
85GXL 600
165GXL 1000
180GXL/190 Gold-HP 1100
160A 1300
210GXL/215 Gold-HP 1200
ALPHA BATTERIES - CONDUCTANCE REFERENCE NOS.

Summary of content (2 pages)