User manual
25 
81 
Deletes all numbers in 
group 1 (Day mode) 
82 
Deletes all numbers in  
group 2 (Night mode) 
83 
Default setting only 
for parameters 3x 
only 3.. 
84 
Default setting only 
for parameters 4x 
only 4.. 
85 
Default setting only 
for parameters 5x 
only 5.. 
9 
E N D 
6  Technical parameters 
6.1  Electrical parameters 
Parameter 
Value 
Conditions 
Minimum line current 
18mA 
line answered 
Minimum line voltage 
18V 
line hang up 
Voltage on line while off hook 
(VA characteristics) 
< 8V 
< 12V 
I = 20mA 
I = 60 mA 
Leakage in hang up status 
< 50uA 
U = 60V 
Impedance of line termination 
130R + 
820R paral. 220n 
line answered 
Bandwidth 
300Hz  3400 Hz 
20 - 60mA 
Impedance of ringing 
> 2Kohm 
25  60 Hz 
Sensitivity of ringing detector 
min. 10  25 V 
Pulse choice  
40 / 60 ms 
Tone choice level 
4 - 6 dB 
20  60 mA 
Tone choice sensitivity 
40 dB 
20  60 mA 
Sensitivity of tone detector 
30 dB 
20  60 mA 
Power supply of lighting through, 
switches and heating 
- 
Max. consumption of lighting 
through and heating 
300mA 
12V 
Max. voltage of switch contact 
48V 
at I < 1A 
Max. current of switch contact 
2A 
at U < 30 V 
Operational temperature  
-  