ALPHATECH TECHNOLOGIES s.r.o. Jeremenkova 88, Praha 4, Czech Republic www.alphatechtechnologies.
Welcome We congratulate you on purchase of “DoorPhone VoIP” (VoIP = Voice over IP), which is the improved version of successful “New DoorPhone” (NUDV). This DoorPhone VoIP will widely manage to satisfy your needs of communication with persons at the building front door or your company entry, or family house doorway. The universality lies in possibility to connect this guard to an Ethernet network or VoIP exchange or directly to SIP server through internet conection.
Table of Contents DOORPHONE VOIP ................................................................................................... 1 1 BASIC DESCRIPTION....................................................................................... 4 1.1 FEATURES ...................................................................................................... 4 1.2 MODULE ASSEMBLY ...................................................................................... 5 1.3 MODULE FEATURES ....................
1 Basic Description 1.1 Features 4 Modular system allows to connect 4 to 64 buttons Voice communication is supplied only from telephone line Two 16digit numbers (IP adress) with each button Day/night switching Possibility of the call extension by * or # choice Possible to connect two independent locks for door opening Possible use of 5 switch modes (e.g.
1.2 Module Assembly The IPDP structural elements are the basic modules with color camera IPDP-00C or without camera IPDP-00 and extending button modules IPNC1-mod with one button, IPNC2-mod with two buttons, IPNC4-mod, NC-mod4 and NM-mod4 with four buttons. Further it is possible to provide the assembly with numerical keyboard. The complete assembly consists similarly to IPDP system of max. 4 modules in column and max. 3 columns side by side.
1.3 Module Features 1.3.1 IPDP Basic Module The IPDP basic module assembling from modulus IP and motherboard. Positioning setting elements and connectors is on picture 1. Picture 1 Basic module - motherboard The “14 pin black conector” serves the connection of extending modules by means of flat cable.
For IPDP is necessary used the AC voltage of min. 10Vst - max. 15Vst or DC voltage of min. 12Vss to max. 18Vss must be energized to “12V” terminal. This source loading depends on number of modules, since it simultaneously serves feeding of lighting through visiting cards – at max. number of connected modules the demand will not exceed 300mA. This source can be also used for feeding of lock(s), and then it is necessary to consider the electrical lock demand.
Setting voice communication – position trimmers are presetting from manufacture and in majority case agree with, therefore changes setting altering only in necessary case. Basic position of trimmers, sense of rotation and meaning trimmers are illustration on picture 3. Picture 3 Setting of trimmers DIP switch setting basic operation and default setting. See on picture 4.
1.3.2 Extending Module IPNCx-mod, NC-mod4 and NM-mod4 This module is supplied in three designs. The IPNCx-mod module (picture 6) has four buttons and includes the electronics to be connected to the basic module. The NC-mod4 module has four buttons and includes the electronics to be connected to the IPNCx-mod or to previous NC-mod4 module. This module is only connected by flat cable – buttons and lighting through is already interconnected.
The flat cable connection is facilitated by connector locks, preventing from rotation, but to keep the connection routing is imperative. “To IP DoorPhone” is always the routing to the basic module. “To NCmod” is routing to the row end (on last NC-mod.). Picture 6 IPNC4-mod module 1.3.3 IPDP-K Keyboard Module The keyboard module is only connected by flat cable as well as NC-mod4 module. The only difference is that keyboard module is always the last in row (no other module can be connected behind it).
1.4 Installation of DoorPhone VoIP Assembly 1.4.1 Installation on Plaster By installation on plaster the only compact box - Rain-Protective Cover KPDxx is used, which will supersede all mechanical parts (MKxx, Canopy xx and Fixing Frame xx). The installation is made by screwing to the wall by means of dowels. See KPD1 on figure. 1.4.2 Flush-Mounted Installation The MKxx mounting box is built-in wall.
Picture 7 Mechanical assembly parts 12 IPDP - installation and operating instructions
1.6 Focus camera and description of front panel If is need focus picture from camera, so everything is illustration on picture front panel basic module on Picture 8 . Picture 8 front panel of basic module IPDP 1. front panel 2. microphone 3. indication LED 4. turning with objective of camera is focus picture 5. camera 6.
2 DoorPhone VoIP Operation 2.1 Signaling Overview The all-purpose guard signals an acoustic conditions they may occur during operation. Another signaling can be done by means of red LED (placed under microphone hole). You can listen the signaling samples in Nset setting program.
preprogrammed code and the time among presses is not bigger than the set point, then the DoorPhone will pick up and close the corresponding switch (if set in m=1 or m=5 modes) to the period given by seting in parameters. Then it will hang up. 2.2.2 DoorPhone with Keyboard The DoorPhone with keyboard can also include besides the keyboard up to 16 buttons of direct dialing always behaving as to be mentioned in chapter 1.3.3 (page 10) except the code lock. This one is always situated on keyboard.
2.3 Person Inside Object The person inside object is considered a person that is in phone contact with DoorPhone. 2.3.1 Outgoing Call The outgoing call is the call from DoorPhone (caused by visitor). After guard choice the telephone is ringing inside object and the pickuping up will allow speaking to the visitor at door. The code choice can close the switch, if set to m=1 or m=5 modes, change over the Day/Night modes and hang up the DoorPhone.
3 Programming of Parameters 3.1 Basic VoIP settings 3.1.1 Choosing a mode and login It is important to choose a DoorPhone mode first. The DoorPhone can work in the PeerToPeer mode or SIP server mode. The mode setting can be made by a relevant switch (DIP switch see on picture 8). In the SIP server mode is possible to choose SIP server (external). It can be set in a configuration interface of the DoorPhone. Picture 9 DIP switch setting In your web browser enter IP address of the DoorPhone, default is 192.
3.1.2 Language option Language setting can be made in a menu on the left panel. 3.1.3 Network settings Network settings are located in the Network seting menu item. It is possible to use DHCP service (1) or you can enter IP addresses manually. Manual configuration: After making changes click on a save and restart button. 1 – Enable/disable ethernet settings via DHCP 2 – Default value – presetings to the firm settings.
DHCP configuration: After making changes click on a save and restart button. 1 – Enable/disable ethernet settings via DHCP 2 – show automatic DHCP generate IP adress and othet settings 3 – Default value – presetings to the firm settings. After making changes click on a save and restart button (display screen - see page 22).
3.1.4 Peer to peer or SIP server connection The DoorPhone can be set to the peer to peer (P2P) mode or to the SIP server mode by DIP switch (page 17). In P2P mode DoorPhone calling IP adress – in memory buttons (page 27). If you setting SIP server mode by DIP switch, so add in menu item SIP parameters After making changes use the save changes button.
3.1.6 Setting video After making changes use the save changes button. 1 – Resolution display video 2 – Number picture per second (frequency restoring picture) 3 – Setting next parameters of camera 4 – Default value – presetings to the firm settings. After making changes use the save changes button.
3.1.7 Service settings 1 – display current version of firmware in module VoIP and in module doorphone, button switching if is has save history events in basic or enhanced mode - it is important to analyses mistakes and problems. This file it is possible save to PC by click on download log file. 2 – tool for upgrade firmware in module VoIP and in module doorphone, switching automatic - information is in upload fille.
3.2 Setting DoorPhone parameters 3.2.1 Basic Parameters After making changes use the save changes button. 1 – Mode of DoorPhone choice selects number per Day/Night DoorPhone mode or selects numbers of the first and second groups. 2 – Sign for call extension * or # (10sec before call end the DoorPhone will send a notice, then the call may be extended) 3 – Two commands in order to hang up the DoorPhone using both switches [2 digits].
3.2.2 All about relays After making changes use the save changes button. 1 – Relay mode: =1 switch mode – it will close on command or password for period t1/2 (used for electrical locks, gate opening etc.) =2 camera mode – it will close by guard pick up and open by hanging up. =3 lighting mode – it will close by guard pick up and stay closed even for period t1/2 after guard hanging up. =4 bell mode – it will close after button pressing and open after period t1/2 (used for e.g.
2 – password for relay closing from buttons or keyboard [2 to 6 digits]. Total 6 passwords, they are controlled by Day/Night; the combination is entered either by DoorPhone buttons (first 10 buttons) or from attached keyboard (after pressing of key symbol). The relay closing influences the set switch mode and Day/Night switchover. By setting of choice mode of 2 number groups the DoorPhone is permanently in DAY mode.
3.2.3 Time Parameters After making changes use the save changes button. 1 – max. time, for which the DoorPhone is hanging up, this time can be extended during call by sign choice from telephone (* or #) – see page 23. 2 – Number of incoming call rings, the DoorPhone pick up after preseted number of rings. After detection first ring – LED on front panel blinking. The number can be set from 1 to 9. 3 – max.
7 – In default is status of DoorPhone signalling acoustically. If signalling makes problem, so this signalling others tones prohibited. 8 – Default value – presetings to the firm settings. After making changes use the save changes button. 3.2.4 Direct Dialing – Memories After making changes use the save changes button. 1 – telephone number up to 16 digits, we want to store. The numbers are the numbers of the first group or numbers of Day mode. In default setting is table memoirs empty.
4 Technical Parameters 4.1 Electrical Parameters Parameter Value Communication interface VoIP protocol supported Band width Power supply of lighting through, switches and heating Max. consumption Max. voltage of switch contact Max. current of switch contact Operational temperature Conditions Ethernet 10BaseT, 100BaseTx SIP 300Hz – 3400 Hz 12Vss ± 2V , 10-12Vst ± 2V 300mA 48V 2A 12Vss at I < 1A at U < 30 V - 20 to + 50°C 4.2 Mechanical dimensions Type of item MKxx mount. box KPDxx (on plast.)1col.
Guarantee conditions: The product was shop-checked. The producer guarantees that this product will keep the features described in these operating instructions in the course of guarantee provided that the user will be handled with it as described in the operating manual. The guarantee will be extended by period of possible guarantee repair. When claiming in guarantee period please contact your dealer. The producer only will make the guarantee repairs.
ALPHATECH TECHNOLOGIES s.r.o. Jeremenkova 88, Praha 4, Czech Republic www.alphatechtechnologies.cz ALPHATECH TECHNOLOGIES s.r.o. Jeremenkova 88 140 00 Praha 4 Czech Republic VAT: CZ27577350 Company is registered in the Commercial Register administered by the Municipal Court in Prague, Section C, Record 116886 Banking details: Komerční banka, account No.