This page intentionally left blank. Argus Technologies Ltd. Burnaby, British Columbia. Telephone: 604 436 5900 Fax: 604 436 1233 Argus Technologies reserves the right to make changes to the products and information contained in this document without notice. Copyright 2008 Argus Technologies Ltd. Argus® is a registered trademark of Argus Technologies Ltd. All Rights Reserved. Printed in Canada. Visit www.argus.
Rear Access Bullet Breaker Panel, 23” 020-671-B2 The following documents and drawings are included in this manual to provide the necessary information required for routine installation of the unit: • Specifications: 020-671-B1 • Important Safety Instructions and Installation: 020-671-C0 • Outline Drawings: 020-671-06 • Customer Connections: 020-671-08 • Schematic, 23” Panel: 020-671-05 • Schematic, Fuse Alarm Relay: 700-011-05 • Warranty and Service: 048-700-10 • Service Centers: 048-693-10 A
This page intentionally left blank.
Specifications for Argus’ Rear Access Bullet Breaker Panels General Alarm: Jumper selectable Form A (normally open) or Form B (normally closed) contacts Input Termination (typical): 1 pair of 3/8” clearance holes on 1” centers for bus bar or wire lug; See also connections drawing for termination list options Load Termination (typical): 2x1/4”-20 lugs on 5/8” centers (1 per breaker) for up to #2AWG; See also connections drawing for termination list options Breaker Option: AM-type mid-trip plug-in brea
Specifications for Argus’ Rear Access Bullet Breaker Panels Continued Part Numbers and List Options This product is available to order under the following part numbers and list options: Description Part Number/List Option Breaker Panel, 23”, Rear Access...............................................................................................................020-671-20 Breaker Panel, 19”, Rear Access.........................................................................................................
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. Please read this manual prior to use to become familiar with the product’s numerous features and operating procedures. To obtain a maximum degree of safety, follow the sequences as outlined. 2. This manual provides warnings and special notes for the user: a. Points that are vital to the proper operation of the product or the safety of the operator are indicated by the heading: WARNING. b.
TABLE OF CONTENTS 1 INTRODUCTION ............................................................................................................................................................. 1 1.1 1.2 2 INSPECTION.................................................................................................................................................................. 2 2.1 2.2 3 Safety Precautions ....................................................................................................
1 Introduction 1.1 Scope of the Manual This instruction manual explains the installation and interconnection of Argus Technologies’ Rear Access Bullet Breaker Panel. NOTE: To aid the user with installation, frequent reference is made to foldout drawings located at the rear of the manual. 1.2 Product Overview Argus designed this panel for load circuit protection suitable for small to large power applications. Up to 24 plug-in breakers can be installed in a 23” rack model; 18 in a 19” rack.
2 Inspection 2.1 Packing Materials All Argus products are shipped in rugged, double walled boxes and suspended via solid inserts to minimize shock that may occur during transportation. Packaging assemblies and methods are tested to International Safe Transit Association standards. Products are also packaged with Cortex. This plastic wrap contains a corrosive-inhibitor that protects the product from corrosion for up to two years. 2.1.1 Returns for Service Save the original shipping container.
3 Installation This chapter is provided for qualified personnel to install the product, which shall be mounted in a clean and dry environment. NOTE: To aid the user with installation, frequent reference is made to foldout drawings located at the rear of the manual. 3.1 Safety Precautions WARNING Hazardous voltages are present at the input of power systems.
4 Wiring and Connections This chapter provides cabling details and notes on cable sizing for DC applications. NOTE: Refer also to foldout drawings located at the rear of the manual. 4.1 Safety Precautions WARNING Hazardous AC voltages may be present. Ensure power at the AC service panel is off before attempting work on the AC connections. Use a voltmeter to verify the absence of voltage. Clearly mark the correct polarity of the battery leads before commencing work on DC connections.
4.4 Alarm Connections and Configuration Jumper selectable Form A (normally open) or Form B (normally closed) alarm contacts are extended to terminal blocks located on the control circuit behind the unit’s front panel. See customer connection drawing for default.
5 Maintenance Although very little maintenance is required with Argus systems, routine checks and adjustments are recommended to ensure optimum system performance. Qualified service personnel should do repairs. The following table lists a few maintenance procedures for this system. These procedures should be performed at least once a year. WARNING: HIGH VOLTAGE AND SHOCK HAZARD. Use extreme care when working inside the shelf while the system is energized. Do not make contact with live components or parts.
6 Argus Conventions 6.1 Numbering System Argus Technologies uses an eight-digit drawing number system, which is broken into three blocks. The first three digits describe the category of the product; e.g., rectifier or fuse panel. The next three digits indicate the sequence in which the product number was allocated in a particular category.
REVISIONS 2.42 61.4 LTR 1.50 38.1 .76 19.3 TYP. B REV BY DESCRIPTION UPDATED TO REFLECT PART CHANGES DGW DATE APPD 2005/01 1.16 29.3 .63 15.9 7.15 181.5 6.25 158.7 5.28 134 TOP VIEW 23.00 584.2 22.31 566.7 5.25 133.4 21.02 534 .44 11.1 2.25 57.2 .75 19.1 4.00 101.6 5.25 133.4 1.56 39.7 1.00 25.4 FRONT VIEW .81 20.5 5.42 137.7 4.94 125.
1.50 38.1 2.42 61.4 .63 15.9 1.16 29.3 .76 19.3 TYP. 6.25 158.7 7.15 181.5 5.28 134 TOP VIEW 23.00 584.2 22.31 566.7 21.02 534 .438 11.13 2.25 57.2 .750 19.05 4.00 101.6 5.3 133.35 5.25 133.4 1.6 39.74 1.000 25.40 FRONT VIEW 5.422 137.72 .808 20.53 4.94 125.5 RIGHT SIDE VIEW THESE DESIGNS AND SPECIFICATIONS ARE THE PROPERTY OF ARGUS TECHNOLOGIES AND SHALL NOT BE COPIED OR USED FOR MANUFACTURING WITHOUT ITS WRITTEN CONSENT.
30° 1.00 25.4 LIST 97 .55 14.1 .4 10.31 4 PL PART OF LIST 121-125 OUTPUT ADAPTERS 4.47 113.6 3.50 88.9 1.00 25.4 2.92 74.3 1.18 30.1 1.68 42.7 7.79 197.9 LEFT SIDE VIEW RIGHT SIDE VIEW OPTIONAL LIST OPTIONS (SHOWN WITH LIST 50,80) R.W. THESE DESIGNS AND SPECIFICATIONS ARE THE PROPERTY OF ARGUS TECHNOLOGIES AND SHALL NOT BE COPIED OR USED FOR MANUFACTURING WITHOUT ITS WRITTEN CONSENT.
REVISIONS LTR REV BY DESCRIPTION B ADDED PG-3 ALARM CONTACTS C CORRECTED LIST 2 -48VDC JUMPER SETTING - SEE SHEET 3 C CORRECTED PINS OF DETAIL 'A' (TYPICAL ALARM WIRING) DATE APPD DGW 2005/01 CDD SDW 2005/06 CDD 2006/01 MP 3/8" x 1" CTR, FOR BUS BAR OR WIRE LUG CONNECTION 53 45 4 PL 3/8" x 1" CTR, FOR BUS BAR OR WIRE LUG CONNECTION TYPICAL 1/4" x 5/8" CTRS 16 POS'N FOR UP TO #2 WIRE 62 52 53 2 PL 53 53 PART OF LIST123/124/125 3 POS'N OUTPUT ADAPTER 613-424-13 FITS 3/8" LUG ON 1" CTRS F
2x LIST97 INPUT ADAPTERS 3/8" x 1" CTR, 60 DEG. 613-425-13 FOR UP TO 4/0 WIRE EACH 53 45 4 PL LIST97 INPUT ADAPTER 3/8" x 1" CTR, 60 DEG.
ALARM OUT (-) P1 - 24 VDC P2 - 24 VDC P1 - 48 VDC P2 - 48 VDC P2 P1 P2P1 1 P3 P4 NORMALLY OPEN ALARM OUT (-) 1 LIST 1 +24 VDC NORMALLY OPEN P3 P4 LIST 2 -48 VDC FACTORY ALARM BOARD JUMPER SETTINGS ALARM OUT (-) 1 P3 P4 NORMALLY OPEN NOTE: CUSTOMER CAN CHANGE P3 SETTING IF DESIRED LIST 14 +12 VDC LIST 50,81 : DUAL FEED CUSTOMER ALARM CONNECTIONS A PIN 1 - ALARM COMMON PIN 3 & 4 ALARM CONTACTS D PIN 2 - ALARM OUT (-) D DETAIL A TYPICAL ALARM WIRING SCALE 1 : 2 THESE DESIGNS AND SPE
02067105B__P1.
02067105B__P2.
1 2 3 4 5 REVISION DESCRIPTION LTR DATE APPD E PCB REDESIGNED 96.02 WES F PCB REDESIGNED 96.09 D R1 R2 R3 K1 DS1 3K3 1W 680 2W 510 5W 24V 28V 3 (130V) 10K 1W 3K0 5W 3K0 5W 48V 28V 14 (12V) 0ohm 0ohm 150 5W 12V 12V HOT ALARM CONTACTS ALARM OUT (-) COMMON 6 N.O. 5 4 1 9 11 2 4 D1 6 33V 1 TB1 1N5257B R3 510 ohm 5W 24 680 ohm R2 P2 1 NOTES: 8 P4 VOLTS 48 3 ALARM OUT P1 1 13 N.C.
WARRANTY AND SERVICE INFORMATION Technical Support Technical support staff are available for answering general questions related to installation, operation and maintenance of Argus products. In Canada and the USA, call Argus toll free at +1-888-GO-ARGUS (+1-888-462-7487) 7:30 am to 5:00 pm Pacific Standard Time. For emergencies, call +1-888-GO-ARGUS (+1-888-462-7487) 24 hours a day, seven days a week. Customers outside Canada and the USA, call +1-604-436-5547 for technical support.
Service Centers Factory Service Centers Canada and International Argus Technologies Ltd. ATTN: RMA Returns 7033 Antrim Avenue Burnaby, BC, V5J 4M5 Canada Tel: +1 604 436 5900 Fax: +1 604 436 1233 Email: returns@argusdcpower.com USA Argus Technologies Inc. ATTN: RMA Returns 3116 Mercer Avenue Bellingham, WA, 98225 USA Tel: +1-360 756 4904 Fax: +1-360 647 0498 Email: returns-usa@argusdcpower.com Asia-Pacific PCM Electronics (Dong Guan) Co., Ltd.