1. MATERIAL IDENTIFICATION
Product Name:
ADHESIVE GEL (RESIN), PART-A
ChemicalFamily: Epoxy Resin Mixture
Company Name: Eastern Resins Corp.
1174 River Street Woonsocket, RI
02895, USA
BUSINESS PHONE:
EMERGENCY PHONE:
(401) 769-6700
(800) 255-3924
2. COMPOSITION
ExposureLimits
ACGIH OSHA
Chemical Name Wt % TLV-TWA PEL
Epoxy resin Mixture >70 N/E N/E
Titanium Dioxide * <10 10 mg/m3 15 mg/m3
Carbon black* <1 3.5 mg/m3 3.5 mg/m3
Fumed silica* <10 20 mppcf 20mppcf
Specific ingredients are considered a Trade Secret
Abbreviations: N/E - NOT ESTABLISHED
* - Materials are in
Non-Airborne
form
3. HEALTH HAZARDS
PrimaryRoutesofExposure:
Eyes: Yes Skin: Yes Inhalation: Yes
Eye Contact
: May cause irritation and swelling.
SkinContact
: May causeirritationand sensitization. Symptoms can be immediateor delayed several hours.
Inhalation:
May cause irritation
and temporary or permanent sensitization.
Ingestion:
May cause irritation.
Other
: Preexisting skin sensitization may be aggravated by exposure to this product.
4. FIRST AID MEASURES
Eyes:
Flush eyes thoroughly with water for at least 15 minutes while holding eyelids open. Seek medical attention.
Skin:
Remove contaminated clothing. Wipe excess from skin and wash the affected area thoroughly with soap and water. Wash contaminated clothing thoroughly
before reuse.
Inhalation:
Remove to fresh air, and provide oxygen or artificial respiration if needed. Obtain medical attention; symptoms can be delayed up to several hours.
Ingestion:
DO NOT induce vomiting. Give 1-2 cups of water or milk unless the person is drowsy, convulsing, or unconscious. Get medical attention.
5. FIRE FIGHTING MEASURES
Flammable Properties: Flash Point
: >300
o
F (PMCC)
ExplosiveLimits:
Not applicable
Auto-IgnitionTemperature:
Not applicable
Hazardous DecompositionProducts
: Carbon monoxide, carbon dioxide, aldehydes, and other organic substances.
EXTINGUISHING MEDIA AND FIRE FIGHTING INSTRUCTIONS
: When sufficiently large quantities are present, firefighters should be equipped with
full bunker gear, including a positive pressure, NIOSH approved, self-contained breathing apparatus. Extreme heat or water contamination may cause closed
containers to explode.
Extinguishing Media
: Use carbon dioxide, dry chemical or appropriate foam
6. ACCIDENTAL RELEASE MEASURES
Ventilate the spill area and evacuate if necessary. Remove all ignition sources. Dike and contain large spills. Clean-up personnel should use adequate protective
equipment.
7. HANDLING AND STORAGE
Store in a cool; dry place, in closed containers at room temperature. Avoid contact with incompatible materials. Wear protective eyewear, chemical-resistant gloves, and
other protective clothing as appropriate.