1. MATERIAL IDENTIFICATION
ProductName:
NOVOLACFLOOR COATING (RESIN), PART-A
ChemicalFamily: Epoxy Resin Mixture
CompanyName:
Eastern Resins Corp.
1174 River Street
Woonsocket,RI02895,USA
BUSINESS PHONE:
EMERGENCYPHONE:
(401) 769-6700
(800) 255-3924
2. COMPOSITION
ExposureLimits
Chemical Name Wt %
ACGIH
TLV
-
TWA
OSHA
PEL
Epoxy resin Mixture
Titanium Dioxide *
Carbon black*
Specific ingredients are considered a Trade Secret
>70
<10
<1
N/E
10 mg/m3
3.5 mg/m3
N/E
15 mg/m3
3.5 mg/m3
Abbreviations: N/E - NOT ESTABLISHED
* - Materials are in
Non-Airborne
form
3. HEALTH HAZARDS
PrimaryRoutesofExposure:
Eyes: Yes Skin: Yes Inhalation: Yes
Eye Contact
: May cause irritation and swelling.
SkinContact
:Maycauseirritationandsensitization.Symptomscanbeimmediateordelayedseveralhours.
Inhalation:
May cause irritation and temporary or permanentsensitization.
Ingestion:
May cause irritation.
Other
: Preexistingskin sensitization may be aggravated by exposure to this product.
4. FIRST AID MEASURES
Eyes:
Flush eyes thoroughly with water for at least 15 minuteswhile holding eyelidsopen. Seek medical attention.
Skin:
Removecontaminatedclothing.Wipeexcessfromskinandwashtheaffectedareathoroughlywithsoapandwater.Wash
contaminatedclothing thoroughlybefore reuse.
Inhalation:
Remove to freshair,andprovide oxygenor artificialrespirationifneeded.Obtainmedical attention; symptomscan be
delayed up to several hours.
Ingestion:
DONOT inducevomiting. Give 1-2cupsofwater or milkunlessthe person isdrowsy,convulsing,orunconscious. Get
medical attention.
5. FIRE FIGHTING MEASURES
FlammableProperties:Flash Point
: >300
o
F(PMCC)
ExplosiveLimits:
Notapplicable
Auto-IgnitionTemperature:
Not applicable
HazardousDecompositionProducts
: Carbon monoxide, carbon dioxide, aldehydes, andotherorganic substances.
EXTINGUISHING MEDIA AND FIRE FIGHTING INSTRUCTIONS
: When sufficiently large quantities are present,
firefighters should be equipped with full bunker gear, including a positive pressure, NIOSH approved, self-contained breathing
apparatus. Extreme heat or water contamination may cause closed containersto explode.
Extinguishing Media
: Use carbon dioxide, dry chemical or appropriate foam
6. ACCIDENTAL RELEASE MEASURES
Ventilate the spill areaandevacuate if necessary.Removeallignitionsources. Dikeand containlarge spills. Clean-uppersonnel
should useadequate protectiveequipment.