User guide
Alpha Industrial Power Spill Control Barrier System
Revision Date: March 18, 2008
MSDSNo. ANFC(B)
Installation Manual Page 22 of 25
MATERIAL SAFETY DATA SHEET
1. MATERIAL IDENTIFICATION
ProductName:
NOVOLACFLOORCOATING(HARDENER),PART-B
ChemicalFamily: AMINE MIXTURE
CompanyName:
Eastern Resins Corp.
1174RiverStreet BUSINESSPHONE: (401) 769-6700
Woonsocket,RI02895,USA EMERGENCYPHONE:(800)255-3924
2. COMPOSITION
ExposureLimits
ACGIH OSHA
ChemicalName Wt% TLV-TWA PEL
Cycloaliphaticamine 50-70 N/E N/E
Aliphaticamine 30-50 N/E N/E
Specificingredients are considereda TradeSecret
Abbreviations:N/E- NOT ESTABLISHED
*-Materials are in
Non-Airborne
form
3. HEALTH HAZARDS
PrimaryRoutesofExposure: Eyes
: Yes
Skin:
Yes
Inhalation:
Yes
EyeContact
: Cause severe irritationand may cause burn.
SkinContact:
Causeirritationandsensitization.Symptomscanbeimmediateordelayedseveralhours.
Inhalation
: Can cause respiratorytract irritation.
Ingestion:
Can cause nausea,headache, and gastrointestinal irritation.
Other:
Preexisting skin sensitization may be aggravatedby exposure tothis product.
4. FIRST AID MEASURES
Eyes:
Flush eyes thoroughly with water for at least 15 minuteswhile holding eyelidsopen. Seek medical attention.
Skin:
Removecontaminatedclothing.Wipeexcessfromskinandwashtheaffectedareathoroughlywithsoapand water.Wash
contaminatedclothing thoroughlybefore reuse.
Inhalation:
Removetofreshair,andprovideoxygenorartificialrespirationifneeded.Obtainmedicalattention; symptoms canbe
delayed up to several hours.
Ingestion
:DONOT inducevomiting. Give 1-2cupsofwaterormilkunlessthepersonisdrowsy,convulsing, or unconscious. Get
medicalattention.
5. FIRE FIGHTING MEASURES
FlammableProperties:FlashPoint
: >200
o
F(PMCC)
ExplosiveLimits:
Notapplicable
Auto-IgnitionTemperature:
Not applicable
HazardousDecompositionProducts
: oxides of nitrogen, Carbon monoxide, carbon dioxide and other organicmaterials.
EXTINGUISHING MEDIA AND FIRE FIGHTING INSTRUCTIONS
: When sufficiently large quantities are present,
firefighters should be equipped with full bunker gear, including a positive pressure, NIOSH approved, self-contained breathing
apparatus. Extreme heat or water contamination may cause closed containersto explode.
ExtinguishingMedia
: Usecarbondioxide,dry chemical or appropriate foam.
6. ACCIDENTAL RELEASE MEASURES
Ventilate the spill areaandevacuate if necessary.Removeallignitionsources. Dikeand containlarge spills. Flush areawith water