Installation Manual

18
Pro700 Installation and Programming Manual
External loudspeaker
; Set jumpers to pos 1 – 2, EXT LS.
; Connect a 20 ohm loudspeaker to terminals 1 and 8.
- Remote Output function can then not be used.
Remote Output
Door opening (activated by "5" from a priority station during
conversation).
These stations have a 30mA transistor output.
; Set jumpers to pos 2 – 3, REM CON.
- External loudspeaker can then not be connected.
; Connect 12 VDC relay to the screw terminal 3 and 8.
; Connect the door lock magnet via the relay contact.
- External power for the door lock magnet is needed.
5.3 AA703, AA704, AA705, BC735
The 3-pair installation cable is connected to terminals 1/2, 3/4 and 7/8
on screw terminal block TB1 on the printed circuit board NFE1830.
Extra equipment is connected to terminals 5/6 and 9/10 on terminal
block TB1 and to TB2 and TB3 on the same printed circuit board.
The stations have to be opened to get access to the terminal blocks.
External loudspeaker
; Connect a 20 – 50 ohm loudspeaker to terminals TB1 - 5 and 6.
- The loudspeaker can be connected independent of jumper
settings and other equipment.
Remote Output
The built-in relay can carry max. 5 A.
Door opening: (activated by "5" from a priority station during
conversation).
; Set jumper 1 to pos 2 - 3.
; Connect the door magnet in series with its power supply to
terminals TB1 - 9 and 10.
Optional Warning: (active when station is called, cancelled by "2").
; Set jumper 1 to pos 1 - 2.
; Connect the warning device in series with its power supply to
terminals TB1 - 9 and 10.
Remote Input, Emergency Call
External switch in parallel with the keyboard switch "9".
; Connect a closing contact switch to TB2 terminals 1 and 2.
Local Reset
Reset a CAS call-in station by pushing an external switch “X”.
; Connect a closing contact switch to TB2 terminals 3 and 4.
Local Output
A lamp will light when a CAS call-in or doorbell call is made.
; Connect a 5W lamp to TB2 terminals 5 and 6.
- The lamp voltage must correspond to the available power!
EXT LS
REM CON
30 mA
EXT LS
REM CON
1
2
3
1
2
3
1
2
3
4
5
6
7
8
EXT
+ 24 V
1
2
3
4
5
6
7
8
9
10
5A
TB1
OPT WARN
OPT WARN
REM OUT
REM OUT
1
2
3
1
2
3
1
2
3
4
5
6
7
8
9
10
TB1
24V
+
-
Signal
Signal
Power +
Power -
Program
Program
1
2
3
4
5
6
TB2
12-24V
5W
ALARM
RESET CAS
“X
“9”