Installation Manual

23
Pro700 Installation and Programming Manual
6.2 Police Station
Door – Guard – Cell communication
z One AB731 station is located inside a cell.
z Two AB731A stations are located outside two entrance doors.
- Door station no. 30 has a relay for remote door opening.
- Door station no. 31 must be opened manually by a guard.
z The relay in no. 30 is operated from guard station no. 10, 11 or 12
by pressing the “5” button during conversation with no.30.
z Station no.30 and 31 will receive a recorded message or music when
waiting in the call queue. Station no.32 will receive a ringing tone.
z Station no. 30, 31 and 32 can make a call to all guard stations by
pressing the call button.
- The call queue is indicated in the display of no. 10, 11 and 12.
- The calls are accepted one by one by pressing “0” in any of the
guard stations.
z All guard stations can call each other and all substations.
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
1
8
1
8
1
8
AB731A AB731A AB731 AA711AA711AA711
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
POWER
U2
U3
No. 30 No. 31 No. 32 No. 10 No. 11 No. 12
CAS
call-in
CAS
call-in
CAS
call-in
CAS
operator
CAS
operator
CAS
operator
Priority
Priority
Priority
Acknowl. tone
Acknowl. mess.
Acknowl. mess.
Alert tone
Alert tone
Alert tone
30
31
32
10
11
12
12-27Vdc
+
_
ON
ON