Spec Sheet

ABL-VOIPLCC 4G Cellular Interface Adapter (AlphaRefuge™ Series)
Product Specification Sheet
APS1132
Rev. 08/2019
ARCHIT ECTS' AND ENGINEER S'
SPECIFICAT IONS
The 4G Cellular Interface unit(s) shall be
Alpha Communications® ABL-VOIPLCC
AlphaRefuge Series, or approved equal.
The ABL-VOIPLCC shall mount in a suitable
location and shall be powered by a standard
120vac electrical outlet. When used with the
AlphaRefuge Series Area of Refuge
system(s) the unit shall be powered by the
PWRAPC power supply and battery back-up
unit.
T h e ABL-VOIPLCC shall come with the
required cellular antenna and the antenna
shall be installed in a suitable location.
Contractor shall observe all local and
national electrical and building codes.
ABL-VO IPLCC 4G CELLULAR INT ERFACE ADAPT ER
(ALPHAREFUGE SERIES)
FEAT URES
Transmits both voice and data wirelessly
Allows you to use up to (2) elevator phones and the data
output from your elevator monitoring device
2100 series phone performs emergency communication
failure check and provides “alarm output when cellular
network goes down
Places call via IP based cellular accounts. Must setup low
cost IP based account with the ALPHA® approved vendor.
Also a standard 4G LTE cellular account with either Verizon,
AT&T, T-Mobile, or a prepaid account.
Requires standard 15mm x 25mm SIM card.
Includes (2) FXS ports (RJ11) for phone connection and
connection for elevator monitoring device (if monitoring
output is phone based, as opposed to IP based, you can
only connect (1) 2100 series phone, the other FXS port is
for monitoring)
Requires 120vac power with battery backup or PWRAPC
Power Supply unit
Requires two wire connection from elevator phone to
cellular device and either two wire or ethernet from elevator
monitoring device
Surface mounted usually in machine room or location with
strong signal
Includes cellular antenna
VoIP Protocols: SIP v2, SDP, RTP, and RFC 2833
Network Protocols: IPv4, TCP, UDP, DHCP, SNTP, STUN,
HTTP, and PPPoE
Connections: FXS RJ11, LAN, and WAN RJ45 (10/100
BaseT)
Power: 120vac from a backed up source or use PWRAPC
Power Supply unit
Power consumption: 8w
Wall mount enclosure with door
FCC Part 15 compliant
Temperature range -40F to +122F (-40C to +50C)
SPECIFICAT IONS
Dimensions:
10.00"W (254mm) x 11.50"H (293mm) x
5.00"D (127mm) total depth
Alpha Communications
42 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-5599