The VDS150 Duty Station
Refer to Figure 3 for locations, names, and functions of controls and indicators.
Code Calls:
Code calls are indicated by a rapidly ashing CALL PLACED lamp and a rapidly pulsing audible tone. The audible
tone signal cannot be silenced by the TONE OFF switch.
Emergency Calls:
Emergency calls are indicated by a ashing CALL PLACED lamp and a pulsing audible tone. The audible tone signal
cannot be silenced by the TONE OFF switch.
Routine Calls:
Routine calls are indicated by steady illumination of the CALL PLACED lamp and a slowly repeating audible tone.
Slide the TONE OFF switch down to silence the audible tone signal. Slide the TONE OFF switch up to turn the au-
dible tone signal function on.
Improper Operation:
If the call station does not operate as described, contact quali ed service personnel. There are no user serviceable
parts on the VDS150 Duty Stations.
CDL101LED Corridor Dome Light
The CLD101LED Corridor Dome Light includes one white/clear routine call indicator LED located in the top half of the
housing. The LED light is contained to the top half of the visible display area by use of an opaque divider. If desired,
the divider can be removed to allow full illumination of the dome light.
Code Calls:
Code calls are indicated by rapid ashing of the corridor light that is associated with the calling station.
Emergency Calls:
Emergency calls are indicated by ashing of the corridor light that is associated with the calling station.
Routine Calls:
Routine calls are indicated by steady illumination of the corridor light that is associated with the calling station.
LED Replacement:
See System Maintenance Instructions for proper procedures and precautions should you even need to replace de-
fective LED Circuit Boards.
Improper Operation:
If corridor light does not operate as described, contact quali ed service personnel. There are no user serviceable
parts on the CDL101LED Corridor Zone Lights other than the LED Circuit Board Modules. (See “Replacement Parts”
on Page 14)
CDL102LED Corridor Zone Light
The CLD102LED Corridor Zone Light includes 2 indicator LEDs: one white/clear routine call indicator LED, and one red
emergency call indicator LED. The LEDs are seperated by an opaque divider for a high level of color contrast.
Code Calls:
Code calls are indicated by rapid ashing of the red corridor zone light(s) associated with the zone or area from
which an emergency call has been placed.
Emergency Calls:
Emergency calls are indicated by ashing of the red corridor zone light(s) associated with the zone or area from
which an emergency call has been placed.
Routine Calls:
Routine calls are indicated by steady illumination of the white corridor zone light(s) associated with the zone or
area from which a routine call has been placed.
AlphaLinQ™ Visual Nurse Call System • 6