VESTA2 GB2 MONITOR INTRODUCTION First and foremost we would like to thank you for purchasing this product. Our commitment to satisfying our customers can be seen from our ISO-9001 certification and from the manufacturing of products like this one. Its advanced technology and exacting quality control will ensure that customers and users enjoy the many features this system offers.
VESTA2 GB2 MONITOR CHARACTERISTICS - Hands-free monitor. - 4.3” TFT colour screen. - Monitor with simple installation (non-polarised 2 wire BUS). - Capacitive buttons to access and select menu functions: User menu: - Display door panel images. - Display camera images (D-CAM-GB2 module required). - Intercom calls between apartments. - Intercom calls within an apartment. - Calls to the Guard monitor. - Do not disturb mode (door panel or intercom calls are not received).
VESTA2 GB2 MONITOR MONITOR DESCRIPTION a h b i c 1 ON j 2 3 4 6 DIP 5 d k e l f g a. b. c. d. e. f. g. Door release function push button. During standby: Press for 10 seconds to activate/deactivate the “doctor mode” function (function code [9018] must be activated). h. Attachment holes. i. Horizontal cable input. j. Connector. k. BUS connection terminals. l. Con#guration DIP switch. Microphone. 4.3” TFT colour screen. Close push button. Menu push buttons.
VESTA2 GB2 MONITOR MONITOR DESCRIPTION Setting the monitor's address codes (addresses 0 to 31): Dip6: Sets the end of line. Set to ON in monitors where the bus cable terminates. Set to OFF only in intermediate monitors. Dip6 to OFF Dip6 to ON ON 1 DIP 2 3 4 5 6 ON 1 DIP 2 3 4 5 6 Dip1 to Dip5: Set the monitor address (addresses 0 to 31).
VESTA2 GB2 MONITOR INSTALLATION OF THE MONITOR IN A SURFACE BOX Avoid dusty or smoky environments or locations near sources of heat. Positioning the surface box: The upper part of the surface box must be placed at a height of 1.60m. The minimum distance between the sides of the surface box and the closest object must be 5cm. 1.
VESTA2 GB2 MONITOR INSTALLATION OF THE MONITOR IN AN EMBEDDING BOX Avoid dusty or smoky environments or locations near sources of heat. Positioning the embedding box: Make a hole in the wall to position the top of the universal embedding box at a height of 1.60m from the ground. The minimum distance between the embedding box and the closest object must be 5 cm. 1.60m Positioning the embedding box and mounting the terminal block: Pass the cable through the hole made in the embedding box.
VESTA2 GB2 MONITOR OPERATION Monitor description upon receiving a call and during communication: Communication activated. Door 1 activated. Door 2 activated. Elapsed call/communication time. 1 2 00:30 DS-1 Door panel that made the call. End call/communication. Start/stop communication. Activate door release. 1.1 Receiving a call from the door panel: When a call is received, the monitor(s) will play a melody and show the door panel image on the main monitor without alerting the visitor.
VESTA2 GB2 MONITOR OPERATION Continued from the previous page. 1.2 The call is unanswered (resident unavailable): When a call is received, the monitor(s) will play a melody and show the door panel image on the main monitor without alerting the visitor. If the call is not answered within 40 seconds the monitor returns to standby. 00:30 DS-1 1.
VESTA2 GB2 MONITOR 10 OPERATION Continued from the previous page. 1.5 “Doctor mode” function (automatic door opening): Description: The “doctor mode” function allows lock release 1 to activate automatically 6 seconds after making a call from the door panel without having to establish communication or pressing door release push button . The main monitor will display the door panel image without alerting the visitor. The call ends after 40 seconds and the channel is freed.
VESTA2 GB2 MONITOR SCREEN AND VOLUME SETTINGS MENU To adjust contrast, the monitor must be in communication or auto switch-on mode. Then press push button to display the “Contrast” option on screen. Using menu push buttons and , select the required contrast level. Press push button to change the next option, “Brightness”, or press to exit the settings menu. 00:30 Contrast: 5 DS-1 To adjust brightness, the monitor must be in communication or auto switch-on mode.
VESTA2 GB2 MONITOR USER MENU Description of the menu push buttons: Main menu Menu access and function selection push button. Camera/Door Intercom Menu scroll down push button. Playback Menu scroll up push button. Do not disturb Menu back push button. Menu exit push button. To access the menu, the monitor must be in standby. Then press menu push button screen of the main menu.
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. 1. Displaying door panel/camera images: 1.1 To display the image from one of the installed door panels, use push buttons and to go to option “Camera/Door” and press push button . The following selection screen will be displayed. Go to the option corresponding to door panel “DS” from which to visualise an image.
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. 1.2 To display the image from one of the installed cameras (D-CAM-GB2 module required), use`push buttons and to go to option “Camera/Door” and press push button . The following selection screen will be displayed. Use push buttons and to go to the option corresponding to camera “CM” from which to visualise an image.
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. 2. Intercom calls: Use push buttons and to go to option “Intercom” and press push button displayed. First menu screen . The following selection screen will be Selection screen Main menu Select Camera/Door Name List Call Intercom Call Guard Unit Playback Inner call Do not disturb 2.1 To access the intercom calls between apartments function, use push buttons and to go to option “Name List Call” and press push button .
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. In the called apartment the monitor/s will emit a melody indicating an intercom call and display the address of the apartment making the call. Press push button to accept the call and establish communication or press option to cancel it. If the call is accepted, communication will last for one and a half minutes or until push button is pressed again or option is pressed.
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. 2.2 To make a call to the building's guard monitor (if there is one), use push buttons and to go to option “Call Guard Unit” and press push button . The following call screen will be displayed indicating the address 'GU' of the surveillance monitor to be called. A long audible tone con#rms the call is being made.
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. 2.3 To access the intercom calls within an apartment function, use push buttons and to go to option “Inner call” and press push button . The following call screen will be displayed, a long audible tone con#rms the call is being made. A series of short audible tones indicates the call cannot be made because a monitor in the apartment is communicating with the door panel. If the call is being made, press option to cancel the call.
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. 3. Do not disturb mode: Use push buttons be displayed. and to go to option “Do not disturb” and press push button First menu screen Main menu . The following selection screen will Selection screen Do not disturb Camera/Door Normal Intercom 1 hour Playback 8 hours Do not disturb Always 3.1 To activate do not disturb mode, use push buttons and to go to option “Always” and press push button .
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. 3.3 To activate the timed “8 hours” do not disturb mode, use push buttons and to go to option “8 hour” and press push button . Status LED will turn on indicating that the function is activated. The monitor will not receive door panel nor intercom calls. Do not disturb mode will be activated for 8 hours. To deactivate do not disturb mode before the end of the timed 8 hours, see section “3.4 To deactivate do not disturb mode” on page 20.
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. To edit fixed-line or cellular telephone numbers, use push buttons button to display the following telephone number editing screen. Selection screen and to go to option “Edit numbers” and press Editing screen Divert options No divert Input numbers 0 If no answer Divert calls Edit numbers Tel: Press push button and using push buttons and enter the #rst telephone number.
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. 5. Settings (ringtone, ring volume, auto switch-on time and language selection): Use push buttons and to go to option “Settings” and press push button . The #rst selection screen will be displayed. First selection screen Second menu screen Main menu Adjust Divert Ring Tune Light Ring Volume Settings Autoswitch ON Time About Language 5.1 To access the ringtones, use push buttons second selection screen will be displayed.
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. 5.2 To access the ring volume, use push buttons and to go to option “Ring volume” and press push button . The following selection screen will be displayed. Use buttons and to select the ring volume. Press option to exit and return to the #rst selection screen. First selection screen Selection screen Settings Adjust Current: Ring Tune 6 Ring Volume Autoswitch ON Time Language 5.
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. Press option to go to the second menu screen. First selection screen Second menu screen Settings Main menu Ring Tune Divert Ring Volume Light Autoswitch ON Time Settings Language About 6. About (information, default settings and installer setup): Using push buttons will be displayed. and go to option “About” and press push button Second menu screen .
VESTA2 GB2 MONITOR USER MENU Continued from the previous page. Use push buttons and to enter the #rst function code number and then press push button to enter the next function code number; repeat the previous steps until the complete function code number is entered. Con#rm the function code entered by pressing push button . To return to the previous screen, press option . (See installer function codes on page 25). Selection and information screen About Installer setup [ 8000 ] H/W: a1.
VESTA2 GB2 MONITOR SECOND DOOR RELEASE MENU To access the second door release menu, press push button during a call, communication or auto switch-on process. The following selection screen will be displayed. Use push buttons and to select door release 1 1 or door release 2 2 . Second door release menu screen 00:30 00:30 1 2 DS-1 Then press push button . Door 1 activated 1 00:30 DS-1 IMPORTANT: Function code [8014] must be activated in the monitor (see “Installer setup” on pages 24 and 25).
VESTA2 GB2 MONITOR NOTES: 27
29 VESTA2 GB2 MONITOR USER MENU (ANNEX) “Playback” menu option (MM-GB2 module and FA-GB2 power supply required): Description of the menu push buttons: Menu push buttons and status LEDs: Menu access and function selection push button. Main menu Camera/Door Intercom Playback Menu scroll down push button. Manual recording push button: During a call, communication or auto switch-on process. Menu scroll up push button. Do not disturb Menu back push button. Status LED: Fixed: power On.
30 VESTA2 GB2 MONITOR USER MENU (ANNEX) Continued from the previous page. To delete the selected video, press option . “Delete?” will be displayed on the screen. Press push button con#rm the deletion or press option to cancel the deletion and return to the previous screen. Selection screen Selection screen 2016/02/02 2016/02/02 17 : 46' : 12" To exit option “Playback” and return to the #rst menu screen, press push button 17 : 46' : 12" to Delete? .