Chapter 5 Parameter Introductions
or fault, it will record the operating time and will continue from the step where the
inverter stops, and restart at the frequency defined for this step, as shown in Fig.5-5-4.
T1 T2 T3 T4 T6 T7
Run command
f1
f2
f3
f4
f5
f6
f7
Operation Freq.(Hz)
Time
Stopping signal
Continue from the stage where the inverter stops
a1
a2
d3
a3
a4
d5
a5
a6
a7
Operating time
of stage 5
Remnant time
of stage 5
Fig. 5-5-4 PLC start mode 1
Continue to operate at the frequency when the inverter stops
When the inverter stops during PLC operation because of receiving STOP command
or fault, it will record the operating time and the current frequency. It will continue
running at the recorded frequency after restart, as shown in Fig. 5-5-5.
T1 T2 T4 T5
Run command
f1
f2
f3
f4
f5
Operation Freq. (Hz)
Time
Stopping signal
Continue to operate at the frequency when the inverter stops
a1
a2
a3
a4
a5
Remnant time of stage 3
d3
Operating time of stage 3
Fig. 5-5-5 PLC start mode 2
Tips:
The difference between mode 1 and mode 2 is that the inverter can record the operating
frequency when the inverter stops and will run at the recorded frequency after restart in