Chapter 5 Parameter Introductions
Table 5-5-1 Settings of PLC stage
Symbol Acc/Dec time Direction
P0.21,P0.22
F: Forward 1F
Acc/Dec time 1
1r r: Reverse
P2.18,P2.19
2F
Acc/Dec time 2
F: Forward
2r r: Reverse
P2.20,P2.21
3F
Acc/Dec time 3
F: Forward
3r r: Reverse
P2.22,P2.23
4F
Acc/Dec time 4
F: Forward
4r r: Reverse
P5.18 PLC record clear
Range: 0,10
Range: 070
P5.19 Record of PLC steps
P5.20 Operating time of this step
Range: 0.036000.0
Note:
Record of PLC steps (P5.19) records the steps that the PLC currently operating at.
Operating time of this step (P5.20) records the operating time of the step that the PLC
currently operating at.
If P5.18 is set to 1, records of PLC steps (P5.19) and operating time of this step (P5.20)
will be cleared , then the value of P5.18 will recovery to 0.
Tips:
You can start, pause, and reset of PLC operating by setting external terminal function,
which is defined in Group 3.
5.7 Wobble Frequency Operating (Group P6)
P6.00 Wobble frequency operation restart mode
Range: 0,10
0: Restart at the freq. and direction before stop, as shown in Fig. 5-6-2.
1: Restart, as shown in Fig. 5-6-3
P6.01 Save wobble frequency operating parameters
Range: 0,10
0: not save 1: save
Note:
Not save: The inverter does not save the wobble frequency operating parameters when
power is off and restart when power is on.
Save: The inverter will save the wobble-frequency operation parameters such as the
operating frequency, and operating direction (UP/DOWN) when power is off. The
inverter will restart as the mode defined by P6.00 when power is on.
151