Fault
display
Name of
protection
Possible reasons of fault Actions
CCF5 RAM fault
RAM fault of the
control board
Replace the control board
CCF6
CPU
disturbance
Serious interference
MCU of the control
board read-write error
The communication
cable is reverse
connected or the
Data-chosen-switch is
dialed wrong
Press
STOP
RESET
to reset
Add a filter on the side of
power supply
Seek for tech support
PCE
Parameter
copying error
Copy wrong parameter
between the keyboard
and EEPROM of
control board
EEPROM of control
board is damaged
Recopy the parameter
Replace the control board
Seek for tech support
HE
Hall current
detection fault
The inverters current
detection circuit is
faulty
The current sensor is
damaged
Replace the inverter
Seek for tech support
dE
Pulse coder
fault
z Pulses per
revolution or lower
frequency are too
small.
z Terminal (model
3004GB and below:
X4, X5,
35R5GB/37R5PB
and above: X7, X8)
setting is
inconsistent with
the wiring
z encoder wiring error
z motor stall
z The encoder is
damaged
z Set correct pulse
detection method
z Check the pulse input
wiring (Double phases
detected, for 3004GB
and below: A-X4,
B-X5, for
35R5GB/37R5PB and
above: A-X7, B-X8)
z Make sure that the
motor is running
smoothly
z Replace encoder
z Check the input
terminals, seek for
technical support
Attention:
For mid-power/mini-watt inverters(3022G/3030P and the below models),there aren’t